Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.02 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.ValveReferenceValues -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -inputPath=.. -r=../ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.ValveReferenceValues_ida_res.mat -s ida) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/BasicControlValve.mo:40:6-40:225:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.dp_ref": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/BasicControlValve.mo:41:6-41:234:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.rho_ref": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Remove the rho_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/SpecificValveType.mo:55:6-55:225:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref1.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.dp_ref1": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/SpecificValveType.mo:56:6-56:234:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref1.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.rho_ref1": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Remove the rho_ref modifier." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.rho_ref1": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.dp_ref1": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.reference1": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.rho_ref": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.dp_ref": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.reference": Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.3093e-05s [ 0.6%] pre-initialization | | | | | | 0.000215917s [ 5.5%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000407137s [ 10.4%] solver (excl. callbacks) | | | | | | 0.000173529s [ 4.4%] creating output-file | | | | | | 1.1161e-05s [ 0.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00308717s [ 78.8%] simulation | | | | | | 0.00391801s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 467 steps taken | | | | | | 704 calls of functionODE | | | | | | 113 evaluations of jacobian | | | | | | 22 error test failures | | | | | | 2 convergence test failures | | | | | | 6.7694e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.