Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../ThermofluidStream_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step2SaturatedVapor -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -inputPath=.. -r=../ThermofluidStream_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step2SaturatedVapor_ida_res.mat -s ida) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance.p_min >= 611.657 and flowResistance.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheaterAndBoiler.p_min >= 611.657 and preheaterAndBoiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheaterAndBoiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.3624e-05s [ 1.9%] pre-initialization | | | | | | 0.000147719s [ 12.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 7.0673e-05s [ 5.8%] solver (excl. callbacks) | | | | | | 2.2162e-05s [ 1.8%] creating output-file | | | | | | 7.514e-06s [ 0.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.000953345s [ 77.8%] simulation | | | | | | 0.00122504s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 103 steps taken | | | | | | 126 calls of functionODE | | | | | | 33 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 1.0528e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.