Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00144/0.00144, allocations: 71.77 kB / 20.51 MB, free: 1.125 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001479/0.001479, allocations: 165.1 kB / 23.76 MB, free: 4.199 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.45/1.45, allocations: 177.2 MB / 204.1 MB, free: 8.883 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo): time 0.5715/0.5715, allocations: 50.78 MB / 311.3 MB, free: 1.758 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:146:3-158:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:160:3-168:15:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:145:4-157:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:159:5-167:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:320:4-332:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:334:5-342:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 179] Using package ThermalSeparation with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(ThermalSeparation.Examples.Absorption_IdealGases,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases") translateModel(ThermalSeparation.Examples.Absorption_IdealGases,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.002389/0.002389, allocations: 71.89 kB / 463 MB, free: 1.254 MB / 430.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:146:3-158:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:160:3-168:15:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:145:4-157:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:159:5-167:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:320:4-332:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:334:5-342:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. Notification: Performance of FrontEnd - Absyn->SCode: time 0.334/0.3363, allocations: 68.08 MB / 0.5187 GB, free: 18.59 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/WaterBasedLiquid/BaseClasses/package.mo:6:3-23:32:writable] Error: PartialWaterBased is partial, name lookup is not allowed in partial classes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/WaterBasedLiquid/N2_O2_H2O.mo:7:3-25:30:writable] Error: Base class ThermalSeparation.Media.WaterBasedLiquid.BaseClasses.PartialWaterBased not found in scope N2_O2_H2O. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/SourcesSinks/SourceLiquid.mo:6:5-6:92:writable] Error: Class MediumLiquid.BaseProperties not found in scope SourceLiquid. Notification: Performance of FrontEnd: time 0.00233/0.3387, allocations: 0.9295 MB / 0.5196 GB, free: 17.97 MB / 446.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.0854298480553553] Failed to read output from testmodel.py, exit status != 0: 0.3468434999231249 0.35848986400000005 -1.0 Calling exit ...