Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=3600 stepSize=1 Regular simulation: ./Modelica_trunk_Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater -abortSlowSimulation -alarm=480 -s ida -emit_protected -lv LOG_STATS LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Examples/AST_BatchPlant.mo:657:7-657:45:writable] | | | | The following assertion has been violated at time 594.658100 | | | | ((B5.m_flow_BottomPorts[1] >= -1e5 and B5.m_flow_BottomPorts[1] <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= B5.m_flow_BottomPorts[1] <= 0.0, has value: 4.29858e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 594.658100 | | | | ((B6.topPorts[1].m_flow >= 0.0 and B6.topPorts[1].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= B6.topPorts[1].m_flow <= 1e5, has value: -3.63734e-05" LOG_ASSERT | debug | Solving non-linear system 4069 failed at time=740.575501030307. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | info | ##IDA## -8 error occurred at time = 740.575076106414 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 740.575 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0627388s reading init.xml | | | | | | 0.00465804s reading info.xml | | | | | | 0.00211481s [ 0.0%] pre-initialization | | | | | | 0.0192953s [ 0.5%] initialization | | | | | | 0.00376707s [ 0.1%] steps | | | | | | 0.0229987s [ 0.5%] solver (excl. callbacks) | | | | | | 0.00906495s [ 0.2%] creating output-file | | | | | | 0.0794634s [ 1.9%] event-handling | | | | | | 0.0114277s [ 0.3%] overhead | | | | | | 4.10905s [ 96.5%] simulation | | | | | | 4.25718s [100.0%] total | | | | | events | | | | | | 36 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 570 steps taken | | | | | | 816 calls of functionODE | | | | | | 332 evaluations of jacobian | | | | | | 29 error test failures | | | | | | 5 convergence test failures | | | | | | 1.8086s time of jacobian evaluation