Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr LibRAS_LibRAS.Examples.TinyRAS.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001957/0.001957, allocations: 82.8 kB / 20.56 MB, free: 1.242 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002538/0.002538, allocations: 170.5 kB / 23.8 MB, free: 4.434 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.399/1.399, allocations: 158.6 MB / 185.6 MB, free: 6.207 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo): time 0.02783/0.02783, allocations: 4.273 MB / 242.1 MB, free: 14.83 MB / 238.1 MB " [Timeout remaining time 180] Using package LibRAS with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(LibRAS.Examples.TinyRAS,tolerance=0.0001,outputFormat="empty",numberOfIntervals=2880,variableFilter="",fileNamePrefix="LibRAS_LibRAS.Examples.TinyRAS") translateModel(LibRAS.Examples.TinyRAS,tolerance=0.0001,outputFormat="empty",numberOfIntervals=2880,variableFilter="",fileNamePrefix="LibRAS_LibRAS.Examples.TinyRAS") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: LibRAS requested package Modelica of version 3.2.2. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002518/0.002518, allocations: 75.52 kB / 358.6 MB, free: 14.66 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.101/0.1035, allocations: 50.45 MB / 409 MB, free: 12.09 MB / 334.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/Tanks/FishTank.mo:26:33-26:43:writable] Error: Modified element unit not found in class Integer. Notification: Performance of FrontEnd: time 0.2516/0.3551, allocations: 39.69 MB / 448.7 MB, free: 4.457 MB / 350.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.6741873159771785] Failed to read output from testmodel.py, exit status != 0: 0.36208835698198527 0.37415926800000004 -1.0 Calling exit ...