Environment - simulationEnvironment: startTime=0 stopTime=36000 tolerance=1e-08 numberOfIntervals=2500 stepSize=14.4 Regular simulation: ./IDEAS_IDEAS.Fluid.Sensors.Conversions.Examples.To_VolumeFraction -abortSlowSimulation -alarm=480 -s ida -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senCO2.warnAboutOnePortConnection)) --> "Sensor To_VolumeFraction.senCO2 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in To_VolumeFraction.senCO2." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00652123s reading init.xml | | | | | | 0.000666019s reading info.xml | | | | | | 0.000216786s [ 2.0%] pre-initialization | | | | | | 0.000260318s [ 2.5%] initialization | | | | | | 2.114e-06s [ 0.0%] steps | | | | | | 0.00137365s [ 13.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 9.79382e-22s [ 0.0%] event-handling | | | | | | 0.00125397s [ 11.8%] overhead | | | | | | 0.00744192s [ 70.2%] simulation | | | | | | 0.0106024s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 605 steps taken | | | | | | 1027 calls of functionODE | | | | | | 72 evaluations of jacobian | | | | | | 32 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000274656s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.