Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWaterTSet -abortSlowSimulation -alarm=480 -s ida -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0192976s reading init.xml | | | | | | 0.00128017s reading info.xml | | | | | | 0.000256031s [ 1.3%] pre-initialization | | | | | | 0.000403166s [ 2.0%] initialization | | | | | | 2.936e-06s [ 0.0%] steps | | | | | | 0.00185417s [ 9.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 3.8011e-05s [ 0.2%] event-handling | | | | | | 0.00541824s [ 26.8%] overhead | | | | | | 0.0122805s [ 60.6%] simulation | | | | | | 0.020253s [100.0%] total | | | | | events | | | | | | 13 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 852 steps taken | | | | | | 1040 calls of functionODE | | | | | | 212 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000502021s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.