Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001873/0.001873, allocations: 82.33 kB / 19.77 MB, free: 2.016 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002354/0.002354, allocations: 152.3 kB / 23.01 MB, free: 4.965 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.439/1.439, allocations: 177.2 MB / 203.4 MB, free: 8.953 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo): time 2.864/2.864, allocations: 394.2 MB / 0.6387 GB, free: 11.95 MB / 0.6075 GB " [Timeout remaining time 176] Using package Buildings with version 13.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR|hrc.hrc.chi.COP|hrc.hrc.chi.EER",fileNamePrefix="Buildings_latest_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR|hrc.hrc.chi.COP|hrc.hrc.chi.EER",fileNamePrefix="Buildings_latest_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002122/0.002122, allocations: 67.89 kB / 1.009 GB, free: 14.49 MB / 0.9669 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8952/0.8973, allocations: 181.8 MB / 1.187 GB, free: 16.2 MB / 1.076 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller): time 0.1845/1.082, allocations: 155.7 MB / 1.339 GB, free: 10.27 MB / 1.186 GB Notification: Performance of NFInst.instExpressions: time 0.08044/1.162, allocations: 46.73 MB / 1.384 GB, free: 11.42 MB / 1.232 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01176/1.174, allocations: 321.6 kB / 1.385 GB, free: 11.1 MB / 1.232 GB Notification: Performance of NFTyping.typeComponents: time 0.01493/1.189, allocations: 4.54 MB / 1.389 GB, free: 6.539 MB / 1.232 GB Notification: Performance of NFTyping.typeBindings: time 0.02269/1.212, allocations: 7.784 MB / 1.397 GB, free: 14.73 MB / 1.248 GB Notification: Performance of NFTyping.typeClassSections: time 0.01456/1.226, allocations: 5.753 MB / 1.402 GB, free: 8.992 MB / 1.248 GB Notification: Performance of NFFlatten.flatten: time 0.0587/1.285, allocations: 38.28 MB / 1.44 GB, free: 2.672 MB / 1.279 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Templates/Plants/HeatPumps/Components/Validation/HeatRecoveryChiller.mo:159:3-160:89:writable] Error: Cannot connect expandable connector busPumHeaWatHrc with non-expandable connector bus.pumHeaWatHrc. Notification: Performance of FrontEnd: time 0.002715/1.288, allocations: 1.136 MB / 1.441 GB, free: 1.488 MB / 1.279 GB " [Timeout remaining time 299] [Calling sys.exit(0), Time elapsed: 7.108991649001837] Failed to read output from testmodel.py, exit status != 0: 1.2953735799528658 1.309179785 -1.0 Calling exit ...