Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Templates.Components.Validation.Pumps.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001371/0.001371, allocations: 85.38 kB / 19.76 MB, free: 2.023 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001394/0.001394, allocations: 159.5 kB / 23.01 MB, free: 4.961 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.42/1.42, allocations: 177.2 MB / 203.4 MB, free: 8.949 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo): time 2.914/2.914, allocations: 394.2 MB / 0.6386 GB, free: 11.93 MB / 0.6075 GB " [Timeout remaining time 176] Using package Buildings with version 13.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_latest_Buildings.Templates.Components.Validation.Pumps") translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_latest_Buildings.Templates.Components.Validation.Pumps") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.003336/0.003336, allocations: 67.89 kB / 1.009 GB, free: 14.47 MB / 0.9669 GB Notification: Performance of FrontEnd - Absyn->SCode: time 1.087/1.09, allocations: 181.8 MB / 1.187 GB, free: 16.18 MB / 1.076 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Components.Validation.Pumps): time 0.4567/1.547, allocations: 406.5 MB / 1.584 GB, free: 14.57 MB / 1.436 GB Notification: Performance of NFInst.instExpressions: time 0.1565/1.703, allocations: 91.03 MB / 1.672 GB, free: 3.309 MB / 1.514 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01979/1.723, allocations: 0.7283 MB / 1.673 GB, free: 2.574 MB / 1.514 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/Characteristics/flowParameters.mo:5:3-6:57:writable] Error: Dimension 1 of 'V_flow' could not be deduced from the component's binding equation 'datPumMul.per.pressure.V_flow'. Notification: Performance of FrontEnd: time 0.003765/1.727, allocations: 1.273 MB / 1.674 GB, free: 1.301 MB / 1.514 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 7.676606163033284] Failed to read output from testmodel.py, exit status != 0: 1.7373615129617974 1.749216098 -1.0 Calling exit ...