Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Buildings_latest_Buildings.Fluid.CHPs.OrganicRankine.BaseClasses.Validation.DryFluid -abortSlowSimulation -alarm=800 -s ida -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00351979s reading init.xml | | | | | | 0.00026124s reading info.xml | | | | | | 0.000264636s [ 6.4%] pre-initialization | | | | | | 0.000103033s [ 2.5%] initialization | | | | | | 9.22e-07s [ 0.0%] steps | | | | | | 6.487e-06s [ 0.2%] solver (excl. callbacks) | | | | | | 0.000486293s [ 11.8%] creating output-file | | | | | | -8.99973e-22s [ -0.0%] event-handling | | | | | | 0.000469112s [ 11.4%] overhead | | | | | | 0.00277879s [ 67.3%] simulation | | | | | | 0.00414401s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2500 steps taken | | | | | | 2500 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.