Environment - simulationEnvironment: startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.ZoneCapacitanceMultiplier -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.22 14:07 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.22 14:07 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((mulCap.duc.m_flow >= 0.0 and mulCap.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= mulCap.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((defCap.duc.m_flow >= 0.0 and defCap.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= defCap.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0143925s reading init.xml | | | | | | 0.00111358s reading info.xml | | | | | | 0.000187502s [ 0.0%] pre-initialization | | | | | | 10.7872s [ 96.6%] initialization | | | | | | 0.000466196s [ 0.0%] steps | | | | | | 0.022852s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.294896s [ 2.6%] event-handling | | | | | | 0.00476652s [ 0.0%] overhead | | | | | | 0.0604964s [ 0.5%] simulation | | | | | | 11.1709s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 720 time events | | | | | solver: ida | | | | | | 11998 steps taken | | | | | | 13730 calls of functionODE | | | | | | 9534 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0424084s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 5.94sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.56sec EnergyPlus Completed Successfully.