Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature -abortSlowSimulation -alarm=400 -s ida -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Integers/Sources/TimeTable.mo:14:3-16:72:writable] | | | | The following assertion has been violated at time 21600.000000 | | | | ((mode.y[1] >= 0 and mode.y[1] <= 1)) --> "Variable violating min/max constraint: 0 <= mode.y[1] <= 1, has value: 2" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -1.96966e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -1.97078e-35" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.82873e-35" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79280.640000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -4.33425e-248" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 79280.640000 | | | | ((con.pum.pumSpe.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.heaDis.etaHyd, has value: -1.95285e-244" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79626.240000 | | | | ((pum.pumDp.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumDp.eff.yMot, has value: -1.30666e-29" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0953624s reading init.xml | | | | | | 0.00746386s reading info.xml | | | | | | 0.00379487s [ 0.9%] pre-initialization | | | | | | 0.00175691s [ 0.4%] initialization | | | | | | 0.000180668s [ 0.0%] steps | | | | | | 0.0324381s [ 8.0%] solver (excl. callbacks) | | | | | | 0.00904346s [ 2.2%] creating output-file | | | | | | 0.00181917s [ 0.4%] event-handling | | | | | | 0.0331908s [ 8.1%] overhead | | | | | | 0.325752s [ 79.8%] simulation | | | | | | 0.407976s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 5 time events | | | | | solver: ida | | | | | | 3271 steps taken | | | | | | 5279 calls of functionODE | | | | | | 799 evaluations of jacobian | | | | | | 271 error test failures | | | | | | 52 convergence test failures | | | | | | 0.109582s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.