Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00126/0.00126, allocations: 83.89 kB / 19.76 MB, free: 2.023 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001339/0.001339, allocations: 156.8 kB / 23 MB, free: 4.961 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.378/1.378, allocations: 177.2 MB / 203.4 MB, free: 8.953 MB / 190.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo): time 0.848/0.848, allocations: 110.3 MB / 370.1 MB, free: 15.7 MB / 350.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:44:3-56:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:58:3-65:19:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:67:3-72:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:74:3-79:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 179] Using package BuildSysPro with version 3.6.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=8,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=8,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") [Timeout 660] "Notification: BuildSysPro requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002045/0.002045, allocations: 70.73 kB / 0.5483 GB, free: 13.34 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:44:3-56:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:58:3-65:19:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:67:3-72:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BoundaryConditions/Scenarios/CombiTimeTable.mo:74:3-79:20:writable] Warning: External function annotation should occur on the external-clause, not on the function. Notification: Performance of FrontEnd - Absyn->SCode: time 0.1431/0.1451, allocations: 87.86 MB / 0.6341 GB, free: 5.332 MB / 0.5919 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.003538/0.1486, allocations: 2.202 MB / 0.6362 GB, free: 3.113 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.0008797/0.1495, allocations: 458.4 kB / 0.6366 GB, free: 2.664 MB / 0.5919 GB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.284151977975853] Failed to read output from testmodel.py, exit status != 0: 0.15701795695349574 0.171048256 -1.0 Calling exit ...