OpenModelica wasm-jit from 2026-09-16 21:27:04 to 2026-09-17 20:00:54

Summary

OMC Commits15
Libraries Changed3
Number of Improvements7
Number of Regressions68
Number of Performance Improvements19
Number of Performance Regressions65

OpenModelica Changes

CommitDateAuthorSummary
237eaefe1d2026-09-17 19:14:08 +0200Andreas[Testsuite] Drop MSL 2.2 from the testsuite (#16420)
9bd4c03c342026-09-17 19:02:59 +0200kabdelhakNB: fix checkLinearity examining never-refined solvability for continuous loops (#16757)
1843fff2642026-09-17 18:19:26 +0200Per ÖstlundSimplify the result in simplifySumProduct (#16755)
0917cfbbce2026-09-17 18:07:58 +0200Martin SjölundUpdate Rust dependencies to their latest releases (#16748)
a3913e6fe82026-09-17 18:07:17 +0200Martin SjölundHold the frontend's upward references weakly (#16696)
02c82b6dc52026-09-17 17:42:29 +0200Adeel AsgharEnable the diagram view for encrypted models (#16754)
5544dbed042026-09-17 17:15:54 +0200kabdelhakNB: fix corrupted resizable-sparsity-pattern rows for multi-dim array equations (#16746)
dcb27e1c312026-09-17 16:39:45 +0200AndreasCMake: configure without testsuite/ and doc/ (#16752)
fd919ff2b22026-09-17 16:35:23 +0200Per ÖstlundDon't evaluate ranges with iterators (#16749)
8b0c5d883e2026-09-17 16:05:39 +0200kabdelhakNB: fix storedRelations[] slot collisions for for-loop-wrapped state events (#16745)
8aa99065662026-09-17 15:42:53 +0200Adeel AsgharRemove static DPI awareness declarations from manifest (#16751)
280da1f8102026-09-17 13:43:04 +0200Adeel AsgharRun OMEdit testsuite with qt6 (#16734)
c52afd1cb52026-09-17 10:20:00 +0200kabdelhakNB: fix Jacobian/sparsity for set-subscripted sliced tearing variables (#16739)
cb6deae7082026-09-17 10:16:19 +0200Adeel AsgharAdd timeout to language server download (#16742)
f4ee5572a72026-09-17 09:12:17 +0200Martin SjölundBuild the C++ runtime in every nightly stage (#16740)

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
a1583bb2026-09-17 07:45:45 +0200Martin SjölundTotal what the two runs spent per phase
1de2afa2026-09-17 07:35:47 +0200Martin SjölundPublish the pull request report before commenting

Library Changes

LibraryChange
Buildings_11Configuration hash (OMC settings or the testing script changed)
Buildings_12Configuration hash (OMC settings or the testing script changed)
Buildings_latestFrom version 14.0.0-master (b0774846b2c09ee674bca84a4f0a19c1ddc5f4e1) to 14.0.0-master (a3cfdde4e2fa1605f351875c2199b6aafaee7fe0)

Models Affected

AixLibAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.BookTrading (sim)Compile → Simulate
AixLibAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.NetworkCommunication1 (sim)Simulate performance 0:04:00 → 0.01
AixLibAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.NetworkCommunication2 (sim)Simulate performance 0:04:00 → 0.01
AixLibAixLib.Controls.HVACAgentBasedControl.Examples.BuildingHeatingSystems.BuildingHeating (sim)Compile → Failed
AixLibAixLib.Fluid.Geothermal.Aquifer.Validation.SimulationTest (sim)Simulate → Failed
AixLibAixLib.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Measured_SmallScale (sim)Simulate performance 13.38 → 6.54
AixLibAixLib.ThermalZones.HighOrder.Validation.EmpiricalValidation.TwinHouseN2 (sim)Compile → Templates
AixLibAixLib.ThermalZones.HighOrder.Validation.EmpiricalValidation.Warehouse (sim)Compile → Templates
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SkyTemperature.Examples.BlackBody (sim)Simulate performance 0.12 → 13.61
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.BaseClasses.Examples.AltitudeAngle (sim)Simulate performance 0.19 → 13.31
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.BaseClasses.Examples.IncidenceAngle (sim)Simulate performance 0.12 → 13.39
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.BaseClasses.Examples.SolarAzimuth (sim)Simulate performance 0.12 → 13.71
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.BaseClasses.Examples.SolarHourAngle (sim)Simulate performance 0.12 → 13.23
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.BaseClasses.Examples.WallSolarAzimuth (sim)Simulate performance 0.12 → 13.00
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.Examples.IncidenceAngle (sim)Simulate performance 0.12 → 13.30
BuildSysProBuildSysPro.IBPSA.BoundaryConditions.SolarGeometry.Examples.ZenithAngle (sim)Simulate performance 0.12 → 13.42
BuildingSystemsBuildingSystems.Buildings.Examples.BuildingThermalMultiZone (sim)Simulate → Compile
BuildingSystemsBuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3 (sim)Simulate performance 0:04:08 → 10.28
BuildingSystemsBuildingSystems.Buildings.Zones.Examples.SingleZoneThermal3x3x3WithOpenings (sim)Simulate performance 0:04:08 → 10.02
BuildingSystemsBuildingSystems.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT (sim)Simulate → Templates
BuildingSystemsBuildingSystems.Fluid.Geothermal.Aquifer.Validation.SimulationTest (sim)Simulate → Templates
BuildingSystemsBuildingSystems.Fluid.Geothermal.Borefields.Validation.Sandbox (sim)Simulate performance 4.59 → 11.97
Buildings_11Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalSpring (sim)Simulate performance 14.02 → 5.19
Buildings_11Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalSummer (sim)Simulate performance 15.22 → 6.78
Buildings_11Buildings.Controls.DemandResponse.Examples.ClientLBNL90 (sim)Verify → Templates
Buildings_11Buildings.DHC.Examples.Combined.SeriesConstantFlow (sim)Simulate → Compile
Buildings_11Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl (sim)Compile performance 4.41 → 12.07 Simulate performance 0:01:16 → 9.85
Buildings_11Buildings.DHC.Plants.Combined.Examples.AllElectricCWStorage (sim)Simulate → Compile
Buildings_11Buildings.Examples.Tutorial.Boiler.System4 (sim)Verify → Templates
Buildings_11Buildings.Examples.Tutorial.Boiler.System5 (sim)Verify → Templates
Buildings_11Buildings.Examples.Tutorial.Boiler.System6 (sim)Simulate performance 2.42 → 22.94
Buildings_11Buildings.Examples.Tutorial.Boiler.System7 (sim)Simulate performance 3.63 → 24.17
Buildings_11Buildings.Examples.Tutorial.CDL.System1 (sim)Simulate performance 0.19 → 21.25
Buildings_11Buildings.Examples.Tutorial.CDL.System2 (sim)Simulate performance 0.17 → 20.91
Buildings_11Buildings.Examples.Tutorial.CDL.System3 (sim)Simulate performance 0.21 → 20.69
Buildings_11Buildings.Examples.Tutorial.CDL.System4 (sim)Simulate performance 0.29 → 19.74
Buildings_11Buildings.Examples.Tutorial.CDL.System5 (sim)Simulate performance 1.42 → 20.23
Buildings_11Buildings.Examples.Tutorial.CDL.System6 (sim)Simulate performance 1.24 → 19.74
Buildings_11Buildings.Examples.Tutorial.SimpleHouse.SimpleHouse0 (sim)Simulate performance 0.14 → 13.48
Buildings_11Buildings.Examples.Tutorial.SimpleHouse.SimpleHouse1 (sim)Simulate performance 0.12 → 12.32
Buildings_11Buildings.Examples.VAVReheat.Guideline36 (sim)Verify → Compile
Buildings_11Buildings.Fluid.Geothermal.Aquifer.Validation.SimulationTest (sim)Verify → Templates
Buildings_11Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection (sim)Simulate performance 0.84 → 0:04:24
Buildings_11Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection (sim)Simulate performance 0:04:24 → 1.42
Buildings_11Buildings.ThermalZones.Detailed.FLEXLAB.Rooms.Examples.X3WithRadiantFloor (sim)Verify → Compile
Buildings_11Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating (sim)Verify → Compile
Buildings_12Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36 (sim)Simulate performance 10.41 → 2.84
Buildings_12Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalSpring (sim)Simulate performance 17.73 → 7.12
Buildings_12Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalSummer (sim)Simulate performance 20.05 → 9.44
Buildings_12Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalWinter (sim)Simulate performance 15.27 → 5.34
Buildings_12Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Spring (sim)Simulate performance 21.71 → 11.42
Buildings_12Buildings.Airflow.Multizone.Examples.PressurizationData (sim)Simulate performance 10.61 → 0.65
Buildings_12Buildings.Controls.DemandResponse.Examples.ClientLBNL90 (sim)Verify → Templates
Buildings_12Buildings.DHC.ETS.Combined.Examples.ChillerBorefield (sim)Simulate → Compile
Buildings_12Buildings.DHC.Examples.Combined.SeriesConstantFlow (sim)Verify → Compile
Buildings_12Buildings.DHC.Examples.Combined.SeriesVariableFlow (sim)Verify → Compile
Buildings_12Buildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl (sim)Compile performance 4.39 → 24.06
Buildings_12Buildings.DHC.Examples.Cooling.ElectricChillersDirectETS (sim)Compile performance 1.97 → 11.03 Simulate performance 0:04:00 → 14.80
Buildings_12Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ1Valve (sim)Simulate performance 0.71 → 14.60
Buildings_12Buildings.DHC.Loads.BaseClasses.Examples.CouplingRCZ6 (sim)Simulate performance 6.59 → 14.50
Buildings_12Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1 (sim)Simulate performance 7.17 → 21.72
Buildings_12Buildings.DHC.Loads.BaseClasses.Examples.CouplingTimeSeries (sim)Verify → Templates
Buildings_12Buildings.DHC.Loads.BaseClasses.Examples.CouplingTimeSeriesSingleLoop (sim)Verify → Templates
Buildings_12Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution1 (sim)Verify → Templates
Buildings_12Buildings.DHC.Loads.BaseClasses.Validation.FlowDistributionPumpControl (sim)Verify → Templates
Buildings_12Buildings.DHC.Loads.BaseClasses.Validation.SimpleRoomODE (sim)Simulate performance 1.42 → 10.70
Buildings_12Buildings.DHC.Loads.HotWater.Examples.StorageTankWithExternalHeatExchanger (sim)Verify → Templates
Buildings_12Buildings.DHC.Plants.Combined.Examples.AllElectricCWStorage (sim)Simulate → Compile
Buildings_12Buildings.DHC.Plants.Cooling.Examples.ElectricChillerParallel (sim)Simulate performance 0.29 → 12.44
Buildings_12Buildings.Electrical.Examples.RenewableSources (sim)Simulate performance 0.61 → 20.87
Buildings_12Buildings.Examples.VAVReheat.Guideline36 (sim)Verify → Compile
Buildings_12Buildings.Examples.VAVReheat.Validation.Guideline36SteadyState (sim)Compile performance 3.13 → 17.71 Simulate performance 0.20 → 10.96
Buildings_12Buildings.Fluid.Boilers.Validation.BoilerTableEfficiencyCurves (sim)Simulate performance 0.03 → 17.55
Buildings_12Buildings.Fluid.CHPs.BaseClasses.Validation.AssertFuelFlow (sim)Simulate performance 0.01 → 20.71
Buildings_12Buildings.Fluid.CHPs.BaseClasses.Validation.AssertPower (sim)Simulate performance 0.02 → 20.59
Buildings_12Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterFlow (sim)Simulate performance 0.04 → 20.78
Buildings_12Buildings.Fluid.CHPs.BaseClasses.Validation.AssertWaterTemperature (sim)Simulate performance 0.01 → 20.62
Buildings_12Buildings.Fluid.CHPs.BaseClasses.Validation.Controller (sim)Simulate performance 0.02 → 20.09
Buildings_12Buildings.Fluid.CHPs.OrganicRankine.Examples.ORCHotWater (sim)Verify → Templates
Buildings_12Buildings.Fluid.CHPs.Validation.ElectricalFollowing (sim)Verify → Templates
Buildings_12Buildings.Fluid.CHPs.Validation.ThermalFollowing (sim)Verify → Templates
Buildings_12Buildings.Fluid.Geothermal.Aquifer.Validation.SimulationTest (sim)Verify → Templates
Buildings_12Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection (sim)Simulate performance 1.17 → 0:04:24
Buildings_12Buildings.ThermalZones.Detailed.FLEXLAB.Rooms.Examples.X3WithRadiantFloor (sim)Verify → Compile
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater (sim)Simulate performance 0.02 → 12.28
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide (sim)Verify → Templates
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryPlantSide (sim)Verify → Templates
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary (sim)Verify → Templates
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.NonIntegrated (sim)Verify → Templates
Buildings_latestBuildings.Applications.DataCenters.DXCooled.Controls.Validation.AirsideEconomizer (sim)Simulate performance 0.02 → 16.55
Buildings_latestBuildings.Applications.DataCenters.DXCooled.Controls.Validation.Compressor (sim)Simulate performance 0.01 → 15.97
Buildings_latestBuildings.Applications.DataCenters.DXCooled.Controls.Validation.CoolingMode (sim)Simulate performance 0.13 → 17.24
Buildings_latestBuildings.Applications.DataCenters.DXCooled.Examples.DXCooledAirsideEconomizer (sim)Simulate performance 7.14 → 18.66
Buildings_latestBuildings.Controls.DemandResponse.Examples.ClientLBNL90 (sim)Verify → Templates
Buildings_latestBuildings.DHC.Examples.Combined.SeriesVariableFlow (sim)Verify → Compile
Buildings_latestBuildings.DHC.Examples.Combined.SeriesVariableFlowAgentControl (sim)Compile performance 9.99 → 17.30 Simulate performance 0:04:01 → 11.11
Buildings_latestBuildings.DHC.Plants.Combined.Examples.AllElectricCWStorage (sim)Simulate → Compile
Buildings_latestBuildings.Examples.VAVReheat.Guideline36 (sim)Verify → Compile
Buildings_latestBuildings.Fluid.CHPs.BaseClasses.Validation.WarmUpTemperature (sim)Simulate performance 0.02 → 14.47
Buildings_latestBuildings.Fluid.CHPs.BaseClasses.Validation.WarmUpTimeDelay (sim)Simulate performance 0.02 → 13.74
Buildings_latestBuildings.Fluid.CHPs.BaseClasses.Validation.WaterFlowControl (sim)Simulate performance 0.02 → 14.24
Buildings_latestBuildings.Fluid.Chillers.Examples.ElectricEIR (sim)Simulate performance 0.02 → 14.06
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Examples.CarnotWithLosses (sim)Simulate performance 0.04 → 14.43
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Examples.LargeScaleWaterToWater (sim)Simulate performance 0.02 → 14.56
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Examples.Modular (sim)Simulate performance 0.04 → 14.81
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2D (sim)Simulate performance 0.02 → 14.72
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2DLoadDep (sim)Simulate performance 0.05 → 14.61
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2DLoadDep_AirCooled (sim)Simulate performance 0.24 → 14.87
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2DLoadDep_HeatRecovery (sim)Simulate performance 0.04 → 14.49
Buildings_latestBuildings.ThermalZones.Detailed.FLEXLAB.Rooms.Examples.X3WithRadiantFloor (sim)Verify → Compile
Buildings_latestBuildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating (sim)Verify → Compile
Buildings_latestBuildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables (sim)Simulate performance 14.12 → 5.84
Buildings_latestBuildings.ThermalZones.EnergyPlus_24_2_0.Validation.RunPeriod.NegativeStartTime (sim)Simulate performance 13.40 → 5.78
Buildings_latestBuildings.ThermalZones.EnergyPlus_24_2_0.Validation.Schedule.EquipmentScheduleOutputVariable (sim)Simulate performance 14.15 → 5.64
DynawoDynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadRestorative (sim)Simulate performance 0:01:46 → 0:03:04
DynawoDynawo.Examples.RVS.TestCases.TestA.TestAShuntNoRestorative (sim)Simulate performance 0:01:55 → 0:01:00
DynawoDynawo.Examples.RVS.TestCases.TestB.TestBSvcNoLoadReset (sim)Simulate → Compile
Dynawo_devDynawo.Examples.RVS.TestCases.TestA.TestAShuntNoRestorative (sim)Simulate performance 0:03:17 → 0:01:07
Dynawo_devDynawo.Examples.RVS.TestCases.TestB.TestBNoSvcLoadReset (sim)Compile → Verify
Dynawo_devDynawo.Examples.RVS.TestCases.TestB.TestBSvcNoLoadReset (sim)Compile → Verify
IDEASIDEAS.Fluid.Geothermal.Aquifer.Validation.SimulationTest (sim)Simulate → Templates
IDEAS_devIDEAS.Fluid.Geothermal.Aquifer.Validation.SimulationTest (sim)Simulate → Templates
ModelicaTest_3.2.3ModelicaTest.Math.TestMatrices2 (sim)Verify → Compile
ModelicaTest_4.0.0ModelicaTest.Math.TestMatrices2 (sim)Verify → Compile
ModelicaTest_4.1.0ModelicaTest.Math.TestMatrices2 (sim)Verify → Compile
ModelicaTest_trunkModelicaTest.Math.TestMatrices2 (sim)Verify → Compile
Modelica_3.2.3Modelica.Blocks.Examples.Rectifier6pulseFFT (sim)Verify → Templates
Modelica_4.0.0Modelica.Blocks.Examples.Rectifier12pulseFFT (sim)Verify → Templates
Modelica_4.0.0Modelica.Blocks.Examples.Rectifier6pulseFFT (sim)Verify → Templates
Modelica_4.1.0Modelica.Blocks.Examples.Rectifier12pulseFFT (sim)Verify → Templates
Modelica_4.1.0Modelica.Blocks.Examples.Rectifier6pulseFFT (sim)Verify → Templates
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackagerBitPack_UDP (sim)Compile → Simulate
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_TCPIPServer (sim)Simulate → Compile
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_TCPIPServerMultipleClients (sim)Compile → Simulate
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_UDPAutoBufferSize (sim)Simulate → Compile
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_UDPWithoutReceiveThread (sim)Simulate → Compile
Modelica_trunkModelica.Blocks.Examples.Rectifier12pulseFFT (sim)Verify → Templates
Modelica_trunkModelica.Blocks.Examples.Rectifier6pulseFFT (sim)Verify → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Analytical_2016 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Analytical_20160629 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Analytical_20160704 (sim)Compile performance 4.18 → 16.64 Simulate performance 9.81 → 22.92
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Analytical_20160808 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Measurement_20160626_to_20161004 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Measurement_20160629 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Measurement_20160704 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Comax_Measurement_20160808 (sim)Simulate → Templates
PhotoVoltaics_TGMPhotoVoltaics_TGM.TGM_Trina_Analytical_20160629 (sim)Simulate → Templates
ScalableTestGrids_nooptScalableTestGrids.Models.Type1.Type1_N_4_M_4 (sim)FrontEnd performance 11.55 → 24.72
ScalableTestGrids_nooptScalableTestGrids.Models.Type1.Type1_N_8_M_4 (sim)Compile → FrontEnd
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_80_M_80 (sim)Compile performance 16.43 → 45.19
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80 (sim)Compile performance 18.37 → 49.72
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_112_M_112 (sim)Compile performance 33.16 → 0:03:27
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_80_M_80 (sim)Compile performance 16.40 → 46.56 Simulate performance 4.91 → 11.11
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_80_M_80 (sim)Compile performance 18.33 → 43.08
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80 (sim)Compile performance 20.21 → 43.71
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_112_M_112 (sim)Compile performance 30.28 → 0:03:18
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_80_M_80 (sim)Compile performance 18.88 → 47.80
ThermoSysProThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim)Compile → Simulate
ThermoSysProThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim)Compile → Simulate