OpenModelica v1.22-cpp from 2024-07-10 16:34:37 to 2024-07-16 11:16:45

Summary

OMC Commits0
Libraries Changed2
Number of Improvements12
Number of Regressions1
Number of Performance Improvements20
Number of Performance Regressions0

OpenModelica Changes

CommitDateAuthorSummary

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
b3682912024-06-20 15:15:32 +0200Adrian Popadd MSL maint/4.1.x via 4.1.0-beta.om (#115)
d05586d2024-06-19 18:48:34 +0200Francesco CasellaAdded testing of last released ThermoFluidStream (#113)

Library Changes

LibraryChange
Buildings_latestFrom version 12.0.0-master (c39e4c0a51090593ee45f6dbfacad8bf70fea90f) to 12.0.0-master (a07fc8904d530b227d5ec805b4ca74c0fca06954)
ThermofluidStream_devFrom version 1.1.0-main (0c2935a050de050659a710ab95f265691deaf6b8) to 1.1.0-main (f8e3f7ec284a6ec56bf102e8ee782772690a2746)

Models Affected

Buildings_latestBuildings.Applications.BaseClasses.Equipment.Validation.ElectricChillerParallel (sim)Compile performance 34.46 → 17.97
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide (sim)Compile performance 0:02:07 → 0:01:12
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryPlantSide (sim)Compile performance 0:01:38 → 55.93
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary (sim)Compile performance 0:02:22 → 0:01:17
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer (sim)FrontEnd performance 10.27 → 4.78 Compile performance 0:03:13 → 0:01:37
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer (sim)FrontEnd performance 15.42 → 7.83 Compile performance 0:04:30 → 0:02:00
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Examples.NonIntegratedPrimarySecondaryEconomizer (sim)FrontEnd performance 10.06 → 5.30 BackEnd performance 10.89 → 5.10 Compile performance 0:04:15 → 0:01:56
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD100 (sim)Compile performance 25.74 → 13.69
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD200 (sim)Compile performance 25.77 → 13.45
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD300 (sim)Compile performance 25.61 → 13.38
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD400 (sim)Compile performance 25.77 → 13.38
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD500 (sim)Compile performance 27.17 → 13.89
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD600 (sim)Compile performance 25.89 → 13.40
Buildings_latestBuildings.Controls.DemandResponse.Examples.ClientLBNL90 (sim)BackEnd performance 0:02:30 → 57.59
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.FreezeProtection (sim)Simulate → Verify
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.ReliefFanGroup (sim)Compile performance 25.63 → 13.32
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.Validation.Controller (sim)Compile performance 22.74 → 11.61
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.Validation.Controller_UnspecifiedClimate (sim)Compile performance 22.45 → 11.34
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.SetPoints.Validation.ReliefFanGroup (sim)Compile performance 26.98 → 12.48
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.Validation.Controller (sim)Compile performance 23.09 → 11.08
Buildings_latestBuildings.DHC.Examples.Combined.SeriesConstantFlow (sim)Templates → Compile
Buildings_latestBuildings.DHC.Examples.Combined.SeriesVariableFlow (sim)Templates → Compile
Buildings_latestBuildings.Templates.Components.Validation.Tanks (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.HeatRecoveryChillers.Validation.EnableAndModeControl (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.MinimumFlow.Validation.Controller (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.MinimumFlow.Validation.ControllerDualMode (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.MinimumFlow.Validation.Setpoint (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.Pumps.Generic.Validation.StagingHeaderedDeltaP (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.Pumps.Primary.Validation.DisableDedicated (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.StagingRotation.Validation.FailsafeCondition (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.StagingRotation.Validation.LoadAverage (sim)Simulate → Verify
Buildings_latestBuildings.Templates.Plants.Controls.StagingRotation.Validation.StageCompletion (sim)Verify → Simulate
ThermofluidStream_devThermofluidStream.HeatExchangers.Tests.Recuperator (sim)Simulate performance 30.14 → 15.09