OpenModelica v1.21-cpp from 2024-02-19 15:02:30 to 2024-02-27 11:42:10

Summary

OMC Commits0
Libraries Changed2
Number of Improvements0
Number of Regressions0
Number of Performance Improvements0
Number of Performance Regressions20

OpenModelica Changes

CommitDateAuthorSummary

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
65dd7302024-02-23 11:42:54 +0100Francesco CasellaUpdated heavy test timeouts (#59)
304f2a72024-02-07 09:26:52 +0100AndreasSpecify branch and directory for github reference files (#56)

Library Changes

LibraryChange
Buildings_latestFrom version 11.0.0-master (6716d8d7c196a57c76bc4ad3c5200fbb301b6718) to 11.0.0-master (39457d348ea447bbeaa748c77605523cb1da3612)
PowerGrids_devFrom version 2.0.0-develop (b814dab4cfeb084d06fd5f06d797e87ab8836006) to 2.0.0-develop (c88d6d4c6572c3e9914b48f5cc6e94c97d80993a)

Models Affected

Buildings_latestBuildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Summer (sim)Templates performance 0:01:29 → 0:02:55
Buildings_latestBuildings.Airflow.Multizone.Examples.ReverseBuoyancy3Zones (sim)Compile performance 11.91 → 21.68
Buildings_latestBuildings.Applications.BaseClasses.Equipment.Validation.ElectricChillerParallel (sim)Compile performance 17.31 → 30.30
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater (sim)Compile performance 14.13 → 24.93
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide (sim)Compile performance 0:01:09 → 0:02:11
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary (sim)Compile performance 0:01:14 → 0:02:25
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.NonIntegrated (sim)Compile performance 50.00 → 0:01:26
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer (sim)Compile performance 0:01:38 → 0:03:14
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer (sim)Templates performance 7.00 → 13.87 Compile performance 0:02:02 → 0:03:58
Buildings_latestBuildings.Applications.DataCenters.ChillerCooled.Examples.NonIntegratedPrimarySecondaryEconomizer (sim)Templates performance 6.73 → 13.87 Compile performance 0:01:57 → 0:04:03
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD100 (sim)Compile performance 13.61 → 24.11
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD500 (sim)Compile performance 13.45 → 23.07
Buildings_latestBuildings.BoundaryConditions.Validation.BESTEST.WD600 (sim)Compile performance 13.37 → 23.06
Buildings_latestBuildings.Controls.DemandResponse.Examples.ClientLBNL90 (sim)BackEnd performance 0:01:18 → 0:02:59
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.SetPoints.Validation.ReliefFanGroup (sim)Compile performance 13.45 → 24.41
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.Validation.Controller (sim)Compile performance 13.80 → 24.38
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.MultiZone.VAV.Validation.Controller_UnspecifiedClimate (sim)Compile performance 13.03 → 24.11
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.SetPoints.Validation.ReliefFanGroup (sim)Compile performance 14.00 → 24.30
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.Validation.Controller (sim)Compile performance 14.26 → 25.94
Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Validation.Controller (sim)Compile performance 10.41 → 20.08
PowerGrids_devPowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection (sim)
PowerGrids_devPowerGrids.Examples.IEEE14bus.IEEE14busLine1to5Opening (sim)
PowerGrids_devPowerGrids.Examples.IEEE14bus.IEEE14busStaticNetwork (sim)