OpenModelica v1.21-cpp from 2023-07-16 13:26:41 to 2023-07-30 17:49:56

Summary

OMC Commits0
Libraries Changed11
Number of Improvements10
Number of Regressions6
Number of Performance Improvements6
Number of Performance Regressions11

OpenModelica Changes

CommitAuthorSummary

Library Changes

LibraryChange
AixLib_latestFrom version 1.3.2-development (1f18a83cd5c0e4bdaaa9e203dd8d4178745beba3) to 1.3.2-development (cd4a0b55eddcfb592f5e7147ccc6887be00fe261)
Buildings_9From version 9.1.1-maint.9.1.x (3e24fd15b05d9f7b94a1f9d5f3f5cd4a97377821) to 9.1.1-maint.9.1.x (fe949eac55e37009eac827f9bf65170c8ffea389)
Buildings_latestFrom version 10.0.0-master (5c00f9da2dcaeec3e6facd8235544359f197dbb0) to 10.0.0-master (cf0a86765dc49cec6180eb4c79131aff6d870140)
IDEASConfiguration hash (OMC settings or the testing script changed)
ModelicaTest_4.0.0Configuration hash (OMC settings or the testing script changed)
OpenIPSLConfiguration hash (OMC settings or the testing script changed)
ScalableTestGrids_nooptConfiguration hash (OMC settings or the testing script changed)
ScalableTestSuiteConfiguration hash (OMC settings or the testing script changed)
ScalableTestSuite_nooptConfiguration hash (OMC settings or the testing script changed)
ThermofluidStreamFrom version 1.1.0-main (b18851359dc281bbfd3e0080bd14e4502b2ccf51) to 1.1.0-main (1c28fe34e95d06ec5a09212d5aeb9e1668a8d8b6)
TransiEntFrom version 2.0.2-master (2fa73c5e26d9ebddf19a4e82a7b0d6bab588ca68) to 2.0.2-master (894fc2d79200644b62b5c9a477af4a55a954adf5)

Models Affected

AixLib_latestAixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump (sim)FrontEnd → Templates
Buildings_9Buildings.Examples.VAVReheat.Validation.Guideline36SteadyState (sim)SimCode performance 12.20 → 20.95
Buildings_latestBuildings.Experimental.DHC.Examples.Combined.SeriesConstantFlow (sim)Templates → Compile
Buildings_latestBuildings.Experimental.DHC.Examples.Combined.SeriesVariableFlow (sim)Templates → Compile
Buildings_latestBuildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Spring (sim)SimCode performance 7.70 → 15.26
IDEASIDEAS.Buildings.Components.Examples.FacadeShadeExample (sim)FrontEnd performance 14.75 → 26.35
IDEASIDEAS.Buildings.Components.Examples.LightingControl (sim)BackEnd performance 7.72 → 13.87
IDEASIDEAS.Buildings.Components.Examples.NumberOccupants (sim)BackEnd performance 7.73 → 13.27
IDEASIDEAS.Buildings.Components.Examples.RectangularZone (sim)FrontEnd performance 15.10 → 26.39
IDEASIDEAS.Buildings.Components.Examples.RectangularZoneEmbedded (sim)FrontEnd performance 14.99 → 26.05
IDEASIDEAS.Buildings.Components.Examples.ScalingWindow (sim)BackEnd performance 6.94 → 11.92
IDEASIDEAS.Buildings.Components.InterzonalAirFlow.Examples.InterzonalAirFlow (sim)FrontEnd → Templates
IDEASIDEAS.Examples.Tutorial.Example10 (sim)BackEnd performance 4.29 → 11.91
ModelicaTest_4.0.0ModelicaTest.Blocks.FilterTests.AllOptions (sim)Templates → Verify
OpenIPSLOpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3 (sim)SimCode performance 19.00 → 10.11
ScalableTestGrids_nooptScalableTestGrids.GridModelBuilders.Type1Sample_N_2_M_2 (sim)
ScalableTestGrids_nooptScalableTestGrids.Models.Type2.Type2_noTap___N_2_M_2 (sim)
ScalableTestSuiteScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetworkDelayed_N_1280_M_10 (sim)SimCode performance 56.60 → 24.73
ScalableTestSuiteScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetwork_N_1280_M_10 (sim)SimCode performance 32.35 → 11.67
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemAC.ScaledExperiments.DistributionSystemLinear_N_40_M_40 (sim)Templates → Failed
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_160_M_10 (sim)Verify → Templates
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_40_M_40 (sim)SimCode performance 26.93 → 15.13
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80 (sim)Failed → Templates
ScalableTestSuiteScalableTestSuite.Electrical.TransmissionLine.ScaledExperiments.TransmissionLineModelica_N_1280 (sim)SimCode performance 41.85 → 21.43
ScalableTestSuiteScalableTestSuite.Elementary.ParameterArrays.ScaledExperiments.Table_N_200_M_200 (sim)Compile → Failed
ScalableTestSuiteScalableTestSuite.Elementary.SimpleODE.ScaledExperiments.CascadedFirstOrder_N_1600 (sim)Simulate performance 4.77 → 10.42
ScalableTestSuiteScalableTestSuite.Elementary.SimpleODE.ScaledExperiments.CascadedFirstOrder_N_25600 (sim)Templates → Failed
ScalableTestSuiteScalableTestSuite.Elementary.SimpleODE.ScaledExperiments.CascadedFirstOrder_N_3200 (sim)Simulate performance 27.09 → 54.04
ScalableTestSuiteScalableTestSuite.Elementary.Tables.ScaledExperiments.CombiTimeTable_N_16000 (sim)Verify → Failed
ScalableTestSuiteScalableTestSuite.Elementary.Tables.ScaledExperiments.TimeTable_N_16000 (sim)Verify → Failed
ScalableTestSuiteScalableTestSuite.Elementary.WhenEvents.ScaledExperiments.ManyEventsManyConditions_N_8000_M_10 (sim)Failed → Templates
ScalableTestSuite_nooptScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetworkDelayed_N_1280_M_10 (sim)SimCode performance 56.45 → 25.85
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80 (sim)Failed → Templates
ThermofluidStreamThermofluidStream.HeatExchangers.Tests.FlowRes (sim)
TransiEntTransiEnt.Basics.Media.Gases.Check.TestRhoCalculationH2NG7 (sim)Failed → Templates
TransiEntTransiEnt.Consumer.Systems.PVBatteryPoolControl.Controller.Check.CheckPBPDispatcher (sim)Failed → Simulate