OpenModelica oldInst from 2021-02-23 20:32:42 to 2021-02-24 20:33:47

Summary

OMC Commits10
Libraries Changed2
Number of Improvements5
Number of Regressions12
Number of Performance Improvements0
Number of Performance Regressions1

OpenModelica Changes

CommitAuthorSummary
213056efe3Francesco CasellaFixed typo (#7222)
3bf2063a9eLennart OchelRemove obsolete api cancelSimulation_asynchronous (#7223)
b6422943b1perostImprove merging of modifiers with constraining type (#7220)
ae591ef554Adeel AsgharSet the nfapi on startup (#7218)
af12e4745eFrancesco CasellaAdded section on fully specified initial conditions to User's Guide (#7212)
4fa0b4b344Adeel AsgharKeep the NFApi settings (#7215)
f9d347e59eAdeel AsgharAsk the user which version of MSL to load and save that settings (#7211)
f861c675e4Martin SjölundAdd AC_CONFIG_AUX_DIR to libffi for EL7 (#7210)
558c01fe31Francesco CasellaFixed obsolete warning messages (#7213)
19d6b79838Adeel AsgharDo not use hard coded center values (#7214)

3rdParty changes

Note that the 3rdParty libraries changed: 8d1eba09d97f..2abdef81ca3b

Library Changes

LibraryChange
Buildings_latestFrom version 8.0.0 (revision 20210217-150031~git~master) to 8.0.0 (revision 20210224-075912~git~master)
PowerSysProFrom version Version 2.1.2 February 18th, 2021 (revision 2.1.2-20210219-114226~git~master) to Version 2.1.3 February 24th, 2021 (revision 2.1.3-20210224-161848~git~master)

Models Affected

BuildSysProBuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Examples.CylindricalHeatSource (sim)Compile → Simulate
BuildingSystemsBuildingSystems.Buildings.Examples.BuildingThermalMultiZone (sim)SimCode performance 6.20 → 10.66
Buildings_7.0.0Buildings.Utilities.IO.Python36.Functions.Examples.Exchange (sim)Simulate → Compile
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.Actuator.LightsControl (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.Actuator.ShadeControl (sim)FrontEnd → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOneOutputVariable (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOneOutputVariableSummer (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.Schedule.EquipmentSchedule (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.Schedule.EquipmentScheduleOutputVariable (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneCompareZoneTemperatureOutput (sim)Templates → Failed
Buildings_latestBuildings.ThermalZones.EnergyPlus.Validation.ThermalZone.ZoneTemperatureInitialization (sim)Templates → Failed
Modelica_4.0.0Modelica.Blocks.Examples.Modulation (sim)Failed → Verify
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_UDP (sim)Compile → Simulate
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_UDPAutoBufferSize (sim)Simulate → Compile
PowerSysProPowerSysPro.Examples.ExampleWithFMUs.MVLVNetwork (sim)Compile → Simulate
PowerSysProPowerSysPro.Examples.ExampleWithFMUs.MVLVNetworkWithBuses (sim)Compile → Simulate