OpenModelica newInst from 2019-06-04 20:29:09 to 2019-06-05 16:15:38

Summary

OMC Commits1
Libraries Changed0
Number of Improvements2
Number of Regressions5
Number of Performance Improvements10
Number of Performance Regressions23

OpenModelica Changes

CommitAuthorSummary
93a3ce527Martin SjölundAdd tests for alternative OS/compilers

Library Changes

LibraryChange

Models Affected

BuildSysProBuildSysPro.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAITSimulate → Templates
IBPSA_latestIBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.MSLAITSimulate performance 0:02:47 → 0:01:37
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestComponents.Fittings.TestJunctionTraceSubstancesCompile performance 8.38 → 15.45 Simulate performance 19.65 → 35.50
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestComponents.Fittings.TestMultiPortTraceSubstancesSimulate performance 20.16 → 37.75
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestComponents.Pipes.DynamicPipeWithNominalLaminarFlowCompile performance 12.09 → 23.37
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesWithTraceSubstancesTemplates performance 11.20 → 19.17 Simulate performance 19.55 → 34.89
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestComponents.Vessels.TestVolumeCompile performance 7.98 → 14.30 Simulate performance 8.08 → 13.99
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_MomentumSteadyStateCompile performance 12.39 → 22.61
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWaterCompile performance 12.59 → 22.32
ModelicaTest_3.2.1_cppModelicaTest.Fluid.TestPipesAndValves.BranchingPipes1Compile performance 10.09 → 17.15 Simulate performance 32.68 → 56.44
ModelicaTest_3.2.1_cppModelicaTest.MultiBody.Joints.UniversalSphericalBackEnd performance 5.60 → 10.14
ModelicaTest_3.2.2ModelicaTest.Blocks.FilterTests.AllOptionsCompile performance 47.41 → 0:01:23 Simulate performance 7.18 → 12.29
ModelicaTest_3.2.2ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDCMotorCompile performance 25.62 → 43.97 Simulate performance 31.32 → 55.08
ModelicaTest_3.2.2ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDCMotorHeatTransferCompile performance 25.42 → 44.17 Simulate performance 31.89 → 56.30
ModelicaTest_3.2.2ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipeWithNominalLaminarFlowCompile performance 17.65 → 31.29 Simulate performance 8.73 → 15.40
ModelicaTest_3.2.2ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesAndFittingsBackEnd performance 7.01 → 13.57 Compile performance 35.79 → 0:01:02 Simulate performance 21.11 → 38.31
ModelicaTest_3.2.2ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesWithTraceSubstancesCompile performance 26.92 → 47.27
ModelicaTest_3.2.2ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_MomentumSteadyStateSimulate performance 13.74 → 26.97
ModelicaTest_3.2.2ModelicaTest.Fluid.TestExamplesVariants.IncompressibleFluidNetwork_StandardWaterOnePhaseCompile performance 16.85 → 28.93 Simulate performance 33.28 → 58.75
ModelicaTest_3.2.2ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes1Compile performance 8.33 → 14.35 Simulate performance 6.08 → 10.64
ModelicaTest_3.2.2ModelicaTest.MultiBody.InitializationConversion.JointsBackEnd performance 7.64 → 14.44 Compile performance 9.38 → 16.25
ModelicaTest_3.2.2ModelicaTest.MultiBody.Joints.UniversalSphericalCompile performance 8.78 → 16.30 Simulate performance 7.08 → 13.70
ModelicaTest_trunkModelicaTest.Blocks.FilterTests.AllOptionsBackEnd performance 18.67 → 10.70 Compile performance 0:01:59 → 0:01:05
Modelica_3.2.1_cppModelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMEE_RectifierSimulate performance 6.93 → 11.99
Modelica_3.2.1_cppModelica.Fluid.Examples.HeatExchanger.HeatExchangerSimulationBackEnd performance 7.62 → 13.10
Modelica_3.2.1_cppModelica.Mechanics.MultiBody.Examples.Loops.Fourbar1BackEnd performance 10.68 → 18.44
Modelica_3.2.2_cppModelica.Media.Examples.R134a.R134a1Simulate performance 19.51 → 11.13
Modelica_3.2.2_cppModelica.Media.Examples.TestOnly.MixIdealGasAirVerify → Compile
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_UDPAutoBufferSizeSimulate → Compile
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemAC.ScaledExperiments.DistributionSystemLinearIndividual_N_40_M_40Templates → Verify
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemAC.ScaledExperiments.DistributionSystemLinear_N_40_M_40Templates → Verify
ScalableTestSuiteScalableTestSuite.Elementary.WhenEvents.ScaledExperiments.ManyEventsManyConditions_N_8000_M_10Templates → Failed
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80Verify → Failed
ThermoSysProThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACBackEnd performance 48.34 → 26.57 Templates performance 15.21 → 8.74 Compile performance 0:03:08 → 0:01:43
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2Simulate performance 17.96 → 9.44
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicDrumCompile performance 32.49 → 18.30 Simulate performance 13.80 → 7.28
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1Compile performance 33.04 → 18.65 Simulate performance 14.00 → 8.23
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipeCompile performance 30.59 → 17.45
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeatingCompile performance 0:01:04 → 37.24 Simulate performance 47.37 → 26.27
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestVolumes2Compile performance 11.04 → 5.27 Simulate performance 23.32 → 11.29