OpenModelica newInst-daemode from 2020-07-05 13:53:28 to 2020-07-08 03:51:27

Summary

OMC Commits5
Libraries Changed4
Number of Improvements12
Number of Regressions1
Number of Performance Improvements5
Number of Performance Regressions0

OpenModelica Changes

CommitAuthorSummary
fd2d61b3deKarim Abdelhak[NF] further fix discrete real check
fa6d1f2bfchudsonUpdated libraries * libraries db952c7...66b6003 (1): > Bump libraries
d15abc57d9Per Östlund[NF] Add workaround for ModelicaError purity.
30abd44e52AnHeuermannReplace alias var in removed equations
81768a11cfAdeel AsgharCheck for NULL pointer

Library Changes

LibraryChange
ModelicaTest_3.2.3From version 3.2.3 (revision 3.2.3-20200605-114010~git~OM-maint-3.2.3) to 3.2.3 (revision 3.2.3-20200705-234045~git~OM-maint-3.2.3)
ModelicaTest_trunkFrom version trunk (revision 20200702-114023~git~OM-trunk) to trunk (revision 20200706-114105~git~OM-trunk)
Modelica_3.2.3From version 3.2.3 (revision 3.2.3-20200605-114010~git~OM-maint-3.2.3) to 3.2.3 (revision 3.2.3-20200705-234045~git~OM-maint-3.2.3)
PowerGridsFrom version 1.0.0 (revision 1.0.0-22-gb9b9504) to 1.0.0 (revision 1.0.0-24-g893d210)

Models Affected

ModelicaTest_3.2.1ModelicaTest.Media.TestAllProperties.IncompleteMedia.ReferenceMoistAir (sim)Simulate performance 16.85 → 7.43
ModelicaTest_3.2.2ModelicaTest.Media.TestAllProperties.IncompleteMedia.ReferenceMoistAir (sim)Simulate performance 17.24 → 7.13
ModelicaTest_3.2.3ModelicaTest.Media.TestAllProperties.IncompleteMedia.ReferenceMoistAir (sim)Simulate performance 16.34 → 7.23
ModelicaTest_trunkModelicaTest.Media.TestAllProperties.IncompleteMedia.ReferenceMoistAir (sim)Simulate performance 17.55 → 7.28
Modelica_3.2.1Modelica.Media.Examples.ReferenceAir.MoistAir1 (sim)Failed → Verify
Modelica_3.2.1_cppModelica.Media.Examples.ReferenceAir.MoistAir1 (sim)Failed → SimCode
Modelica_3.2.2Modelica.Media.Examples.ReferenceAir.MoistAir1 (sim)Failed → Verify
Modelica_3.2.2_cppModelica.Media.Examples.ReferenceAir.MoistAir1 (sim)Failed → SimCode
Modelica_3.2.3Modelica.Media.Examples.ReferenceAir.MoistAir1 (sim)Failed → Verify
PowerGridsPowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault (sim)Failed → Simulate
PowerGridsPowerGrids.Examples.ENTSOE.TestCase3 (sim)Failed → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection (sim)Simulate performance 27.76 → 3.97
PowerGridsPowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridParametersChange (sim)Failed → Simulate
PowerGridsPowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithControlledGen (sim)Failed → Simulate
PowerGridsPowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithPSS (sim)Failed → Simulate
PowerGridsPowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithoutPSS (sim)Failed → Simulate
PowerGridsPowerGrids.Examples.Tutorial.GridOperation.LoadChange.LoadChangeByInputSignals (sim)Failed → Simulate
ScalableTestSuiteScalableTestSuite.Elementary.WhenEvents.ScaledExperiments.ManyEventsManyConditions_N_8000_M_10 (sim)Verify → Templates