OpenModelica newInst-daeMode from 2023-07-16 05:18:24 to 2023-07-19 03:48:22

Summary

OMC Commits0
Libraries Changed5
Number of Improvements6
Number of Regressions5
Number of Performance Improvements7
Number of Performance Regressions0

OpenModelica Changes

CommitAuthorSummary

Library Changes

LibraryChange
AixLib_latestFrom version 1.3.2-development (1f18a83cd5c0e4bdaaa9e203dd8d4178745beba3) to 1.3.2-development (cd4a0b55eddcfb592f5e7147ccc6887be00fe261)
Buildings_8Configuration hash (OMC settings or the testing script changed)
Buildings_9Configuration hash (OMC settings or the testing script changed)
Buildings_latestFrom version 10.0.0-master (5c00f9da2dcaeec3e6facd8235544359f197dbb0) to 10.0.0-master (ee95108110130a91c46caa0b97fe3346088dd980)
ScalableTestGrids_nooptConfiguration hash (OMC settings or the testing script changed)

Models Affected

AixLib_latestAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.BookTrading (sim)Compile → Simulate
AixLib_latestAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.NetworkCommunication1 (sim)Simulate performance 0:08:00 → 0.07
AixLib_latestAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.NetworkCommunication2 (sim)Simulate performance 0:08:00 → 0.07
AixLib_latestAixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump (sim)FrontEnd → Compile
Buildings_8Buildings.Obsolete.Utilities.IO.Python27.Functions.Examples.Exchange (sim)Simulate → Compile
Buildings_8Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.ASHRAE2006Spring (sim)Simulate performance 12.24 → 3.52
Buildings_8Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.ASHRAE2006Summer (sim)Simulate performance 14.14 → 6.37
Buildings_9Buildings.Occupants.BaseClasses.Validation.Weibull1DOFF (sim)Verify → Simulate
Buildings_9Buildings.Occupants.Office.Windows.Validation.Rijal2007WindowsTInTOutTComf (sim)Simulate → Verify
Buildings_latestBuildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Validation.GFunction_100boreholes (sim)Simulate → Verify
Buildings_latestBuildings.Occupants.Residential.AirConditioning.Validation.Ren2014ACLivingroom (sim)Simulate → Verify
ScalableTestGrids_nooptScalableTestGrids.Models.Type1.Type1_N_4_M_4 (sim)Simulate performance 18.73 → 2.42
ScalableTestGrids_nooptScalableTestGrids.Models.Type1.Type1_N_6_M_4 (sim)Simulate → Failed
ScalableTestGrids_nooptScalableTestGrids.Models.Type1.Type1_N_8_M_4 (sim)FrontEnd → Failed
ScalableTestGrids_nooptScalableTestGrids.Models.Type1.Type1_reduced_N_4_M_4 (sim)FrontEnd → Failed
ScalableTestGrids_nooptScalableTestGrids.Models.Type2.Type2_tapEv___N_4_M_4 (sim)Templates performance 34.24 → 18.34
ScalableTestGrids_nooptScalableTestGrids.Models.Type2.Type2_tapNoEv_N_4_M_4 (sim)SimCode performance 16.08 → 8.83
ScalableTestGrids_nooptScalableTestGrids.Models.Type2.Type2_tapNoEv_N_6_M_4 (sim)Failed → Simulate