OpenModelica master from 2025-09-10 22:43:34 to 2025-09-11 14:40:17

Summary

OMC Commits4
Libraries Changed4
Number of Improvements13
Number of Regressions2
Number of Performance Improvements1
Number of Performance Regressions4

OpenModelica Changes

CommitDateAuthorSummary
e4961bb4792025-09-11 12:53:57 +0200AndreasAdding C runtime overview image (#14340)
aefa7e1dfc2025-09-11 12:48:45 +0200Adeel AsgharConstruct the qualified path of variable (#14341)
82aab0f0112025-09-11 00:08:46 +0200phannebohm[NF] Fix applyShallow for matrix (#14311)
d13ef32b5a2025-09-10 23:46:11 +0200phannebohm[NB] Differentiate `identity` and `linspace` (#14338)

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
a0b19ca2025-09-10 15:42:35 +0200Francesco CasellaAdded Pharmacolibrary to tested library (#221)
78b314a2025-07-23 14:25:23 +0200Francesco CasellaUpdate heavy_tests.json (#218)

Library Changes

LibraryChange
Buildings_11From version 11.1.1-maint.11.x (efa269d234673e79bf5a16c78a68ec7d7a9c3134) to 11.1.1-maint.11.x (5c4520d8a9f0bb1772569243c7a3920b8be21cff)
Buildings_latestFrom version 13.0.0-master (fe465836d202da9a515cb8c1a18819ed968e7242) to 13.0.0-master (4cbd5cd5134775fdb6f31c321a26cd0a53e50905)
ThermofluidStreamConfiguration hash (OMC settings or the testing script changed)
ThermofluidStream_devConfiguration hash (OMC settings or the testing script changed)

Models Affected

AixLibAixLib.Systems.ModularAHU.Examples.EONERC_AHU2 (sim)BackEnd performance 10.13 → 5.95
Buildings_11Buildings.Examples.VAVCO2.VAVSystemCTControl (sim)Simulate performance 1.81 → 31.45
Buildings_11Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase1 (sim)Simulate → Verify
Buildings_12Buildings.Examples.VAVCO2.VAVSystemCTControl (sim)Simulate performance 2.76 → 33.95
Buildings_12Buildings.Examples.VAVReheat.Validation.TraceSubstance (sim)Simulate performance 0:01:45 → 0:03:03
Buildings_12Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Validation.GFunction_100boreholes (sim)Simulate → Verify
Buildings_12Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase1 (sim)Simulate → Verify
Buildings_latestBuildings.Examples.VAVCO2.VAVSystemCTControl (sim)Simulate performance 2.75 → 32.77
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2DLoadDep (sim)Compile → Verify
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2DLoadDep_AirCooled (sim)Compile → Verify
Buildings_latestBuildings.Fluid.Chillers.ModularReversible.Validation.TableData2DLoadDep_HeatRecovery (sim)Compile → Verify
Buildings_latestBuildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Validation.GFunction_100boreholes (sim)Verify → Simulate
Buildings_latestBuildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase1 (sim)Simulate → Verify
Modelica_4.0.0Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_Conveyor (sim)Verify → Simulate
Modelica_4.1.0Modelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls (sim)Compile → Verify
Modelica_trunkModelica.Fluid.Examples.TraceSubstances.RoomCO2WithControls (sim)Compile → Verify
ThermofluidStreamThermofluidStream.Examples.SimpleAirCycle (sim)Simulate → Verify
ThermofluidStreamThermofluidStream.Examples.SimpleStream (sim)Simulate → Verify
ThermofluidStream_devThermofluidStream.Examples.SimpleAirCycle (sim)Simulate → Verify
ThermofluidStream_devThermofluidStream.Examples.SimpleStream (sim)Simulate → Verify