| Commit | Date | Author | Summary |
| ebdd3203f2 | 2026-08-03 20:23:42 +0200 | Martin Sjölund | Numerical Jacobian: nominal step below atol only (#16176) |
| f3478a7f4a | 2026-08-03 20:06:38 +0200 | cbermperi | [NB] Implement cyclic alias set resolution using Bareiss elimination (#15796) |
| 3f2692fe7f | 2026-08-03 17:36:43 +0200 | Martin Sjölund | wasm-jit: the gbode and rungekutta solvers (#16180) |
| cc71618719 | 2026-08-03 16:11:38 +0300 | Adrian Pop | [Backend] Replace variables under record field accesses (DAE.RSUB) (#16178) |
| ab4d57aa18 | 2026-08-03 13:17:40 +0200 | Martin Sjölund | wasm-jit: the result-file variable filter (#16175) |
| 1ce40ce21f | 2026-08-03 11:00:14 +0200 | Martin Sjölund | wasm-jit: evaluate bound variable attributes (#16171) |
| a218eb7e4c | 2026-08-02 21:57:36 +0200 | Martin Sjölund | wasm-jit: -lv=LOG_NLS and strict simflags (#16170) |
| 411d6f6935 | 2026-08-02 17:25:22 +0200 | Martin Sjölund | wasm-jit: the IDA solver, with sensitivities (#16168) |
| 7aa6cd0f63 | 2026-08-02 13:41:50 +0200 | Martin Sjölund | Numerical Jacobian: floor the FD step at nominal (#16166) |
| 47dee7aaa7 | 2026-08-02 08:28:01 +0200 | Martin Sjölund | wasm-jit: reject an unimplemented method= (#16167) |
| a301474a0a | 2026-08-02 08:26:55 +0200 | Martin Sjölund | wasm-jit: fix the DASSL Jacobian FD step (#16165) |
| 8b1869d36d | 2026-08-01 12:42:44 +0200 | Martin Sjölund | wasm-jit: shared literals and C's NLS start point (#16164) |
| Library | Change |
| Buildings_11 | From version 11.1.2-maint.11.x (https://github.com/lbl-srg/modelica-buildings/archive/df423074e48835df648a03866d9e703d4569114a.zip) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input
OMSimulator v3.0.0.post160-g564cb10-linux
info: 1 warnings
info: 0 errors to 11.1.2-maint.11.x (https://github.com/lbl-srg/modelica-buildings/archive/409edb846408a44d6f0b7cb2fa0eef479e3f0076.zip) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input
OMSimulator v3.0.0.post160-g564cb10-linux
info: 1 warnings
info: 0 errors |
| Buildings_12 | From version 12.1.2-maint.12.x (https://github.com/lbl-srg/modelica-buildings/archive/f04caa0b1ad7c9fb60746762ad73a96b9e67904a.zip) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input
OMSimulator v3.0.0.post160-g564cb10-linux
info: 1 warnings
info: 0 errors to 12.1.2-maint.12.x (https://github.com/lbl-srg/modelica-buildings/archive/927a6b461a7cba8b09d96ca503000d8032fb9529.zip) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input
OMSimulator v3.0.0.post160-g564cb10-linux
info: 1 warnings
info: 0 errors |
| Buildings_latest | From version 14.0.0-master (https://github.com/lbl-srg/modelica-buildings/archive/1bf3839e9de0510b32de2890dffb41264f3f6a85.zip) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input
OMSimulator v3.0.0.post160-g564cb10-linux
info: 1 warnings
info: 0 errors to 14.0.0-master (https://github.com/lbl-srg/modelica-buildings/archive/953f9ed459ecc78ee0a037e8e1542de501192eb6.zip) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input
OMSimulator v3.0.0.post160-g564cb10-linux
info: 1 warnings
info: 0 errors |
| ThermofluidStream | Configuration hash (OMC settings or the testing script changed) |