OpenModelica cpp from 2026-07-06 10:35:21 to 2026-07-06 16:52:51

Summary

OMC Commits7
Libraries Changed0
Number of Improvements1
Number of Regressions2
Number of Performance Improvements3
Number of Performance Regressions4

OpenModelica Changes

CommitDateAuthorSummary
abd17efade2026-07-06 16:41:27 +0300Adrian PopRust: rename daskr module aux -> auxiliary (Windows reserved name) (#15997)
dc282f99252026-07-06 15:36:29 +0200Martin SjölundCurl_wasm: record each pending download only once (#16001)
65b5d576fb2026-07-06 15:28:12 +0200Martin Sjölundweb: SPA launcher for the browser clients (#16000)
ff1d27abd22026-07-06 15:26:10 +0200phannebohm[C] Check sparse pattern availability directly (#15999)
e5e9996e0d2026-07-06 15:06:37 +0200Per ÖstlundMake expandable connector terminology less confusing (#15998)
38c97aae722026-07-06 14:22:42 +0200linuslangenkamp[GBODE] add support for single-point spectrum and lower triangular transforms (#15987)
f90ec2099d2026-07-06 11:57:01 +0200Martin Sjölundwasm-jit: implement the homotopy() operator and continuation (#15996)

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
6697fc02026-07-06 18:25:17 +0200linuslangenkamp[GBODE] set Radau IIA 3-stage, remove embedded error estimate (#288)
d357aff2026-06-12 13:26:07 +0200AndreasFix OMSimulator submodule update when directory layout changes (#287)

Library Changes

LibraryChange

Models Affected

AESAES.Coursework.ThermSys_control_problems.Flow_pressure_control_liquids.Valve_linearisation_case_001a_DT_LargeScale (sim)Templates performance 27.54 → 51.04
BuildSysProBuildSysPro.Systems.HVAC.Emission.Examples.MozartJoulePIControlled (sim)Compile performance 36.71 → 19.80
BuildSysProBuildSysPro.Utilities.Analysis.Examples.RestartDiscomfort (sim)Templates performance 11.38 → 6.41
Buildings_11Buildings.DHC.Plants.Combined.Examples.AllElectricCWStorage (sim)Compile → Templates
Buildings_12Buildings.DHC.Plants.Combined.Examples.AllElectricCWStorage (sim)Templates performance 22.31 → 51.84
OpenIPSL_2.0.0OpenIPSL.Examples.DAEMode.N44_Original_Systems.Nordic44_Original_Case_Line_Opening (sim)Templates performance 54.17 → 31.13
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80 (sim)BackEnd performance 0:01:27 → 0:02:49
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_56_M_56 (sim)Templates → Verify
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_160_M_10 (sim)Simulate performance 4.90 → 10.14
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_320_M_5 (sim)Verify → Templates