OpenModelica cpp from 2024-07-06 01:07:05 to 2024-07-06 16:34:22

Summary

OMC Commits0
Libraries Changed1
Number of Improvements1
Number of Regressions3
Number of Performance Improvements16
Number of Performance Regressions3

OpenModelica Changes

CommitDateAuthorSummary

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
b3682912024-06-20 15:15:32 +0200Adrian Popadd MSL maint/4.1.x via 4.1.0-beta.om (#115)
d05586d2024-06-19 18:48:34 +0200Francesco CasellaAdded testing of last released ThermoFluidStream (#113)

Library Changes

LibraryChange
Buildings_latestFrom version 12.0.0-master (745315ed4816b1420de7e5b2d80afd92775db936) to 12.0.0-master (c39e4c0a51090593ee45f6dbfacad8bf70fea90f)

Models Affected

Buildings_latestBuildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.Validation.Controller (sim)Compile performance 21.26 → 11.93
Buildings_latestBuildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl (sim)Compile performance 29.90 → 16.55
Buildings_latestBuildings.Examples.ChillerPlant.DataCenterContinuousTimeControl (sim)Compile performance 0:01:32 → 53.47
Buildings_latestBuildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl (sim)Compile performance 0:01:38 → 53.05 Simulate performance 14.07 → 7.89
Buildings_latestBuildings.Examples.ChillerPlant.DataCenterRenewables (sim)Compile performance 0:01:47 → 57.72
Buildings_latestBuildings.Examples.DualFanDualDuct.ClosedLoop (sim)FrontEnd performance 27.60 → 14.48 Templates performance 0:01:31 → 45.63
Buildings_latestBuildings.Examples.HydronicHeating.TwoRoomsWithStorage (sim)Templates performance 49.28 → 27.97
Buildings_latestBuildings.Examples.ScalableBenchmarks.BuildingVAV.Examples.TwoFloor_TwoZone (sim)FrontEnd performance 12.04 → 6.46 BackEnd performance 51.06 → 28.99 Templates performance 0:02:14 → 53.74
Buildings_latestBuildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.MultiZone (sim)FrontEnd performance 10.34 → 5.11 Templates performance 0:02:06 → 54.01
Buildings_latestBuildings.Examples.VAVCO2.VAVSystemCTControl (sim)Compile performance 0:02:20 → 0:01:02
Buildings_latestBuildings.Examples.VAVReheat.ASHRAE2006 (sim)Templates performance 0:02:15 → 56.13
Buildings_latestBuildings.Examples.VAVReheat.Guideline36 (sim)BackEnd performance 0:01:17 → 31.22 SimCode performance 11.47 → 2.09 Templates performance 0:04:01 → 0:01:12 Compile performance 11.01 → 5.89
Buildings_latestBuildings.Examples.VAVReheat.Validation.Guideline36SteadyState (sim)BackEnd performance 0:01:20 → 29.46 SimCode performance 11.55 → 4.49 Templates performance 0:03:57 → 0:01:17 Compile performance 11.12 → 5.97
Buildings_latestBuildings.Examples.VAVReheat.Validation.TraceSubstance (sim)BackEnd performance 43.16 → 17.66 Templates performance 0:02:22 → 49.14
Buildings_latestBuildings.Fluid.Examples.FlowSystem.Basic (sim)Simulate performance 7.67 → 23.04
Buildings_latestBuildings.Fluid.Examples.FlowSystem.Simplified2 (sim)Simulate performance 0:04:01 → 0:08:02
Buildings_latestBuildings.Fluid.Examples.FlowSystem.Simplified3 (sim)Simulate performance 11.13 → 32.82
Buildings_latestBuildings.Fluid.Examples.FlowSystem.Simplified5 (sim)Compile → Verify
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolumeMoistureReverseFlowPrescribedHeatFlowRate (sim)Verify → Simulate
Buildings_latestBuildings.Fluid.Movers.Validation.ControlledFlowMachine (sim)Verify → Simulate
Buildings_latestBuildings.Templates.Plants.Controls.Pumps.Generic.Validation.StagingHeaderedDeltaP (sim)Verify → Simulate
Buildings_latestBuildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Unconditioned (sim)Simulate performance 16.97 → 8.46
Buildings_latestBuildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable (sim)Simulate performance 14.43 → 8.12