Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr LargeTestSuite_OB_LargeTestSuite.Thermal.HeatConduction.OneDHeatTransferTT_FD_N_655360.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/LargeTestSuite 2.2.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ScalableTestSuite 2.2.0-master/package.mo", uses=false) Using package ScalableTestSuite with version 2.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ScalableTestSuite 2.2.0-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package LargeTestSuite with version 2.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/LargeTestSuite 2.2.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(LargeTestSuite.Thermal.HeatConduction.OneDHeatTransferTT_FD_N_655360,tolerance=0.0001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="LargeTestSuite_OB_LargeTestSuite.Thermal.HeatConduction.OneDHeatTransferTT_FD_N_655360") translateModel(LargeTestSuite.Thermal.HeatConduction.OneDHeatTransferTT_FD_N_655360,tolerance=0.0001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="LargeTestSuite_OB_LargeTestSuite.Thermal.HeatConduction.OneDHeatTransferTT_FD_N_655360") Thread is still alive. OMC died, but the thread is still running? This will end badly. The log-file of omc: Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.51e9b4ac7d264ecf86e0df9ec1c5af2ammap(PROT_NONE) failed Aborted (core dumped) Aborted the command. Failed to read output from testmodel.py, exit status != 0: Result file HelloWorld_res.mat WAS NOT generated running: ./HelloWorld with flags [ -noemit -s=ida] OMC died, but the thread is still running? This will end badly.