Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4") translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8594/0.8594, allocations: 150.8 MB / 166.6 MB, free: 11.2 MB / 138.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0002522/0.0002523, allocations: 11.98 kB / 204.7 MB, free: 6.172 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1532/0.1534, allocations: 31.33 MB / 236 MB, free: 3.879 MB / 186.7 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4): time 1.602/1.756, allocations: 293.7 MB / 0.5173 GB, free: 8.414 MB / 410.7 MB Notification: Performance of NFInst.instExpressions: time 0.4932/2.249, allocations: 184.4 MB / 0.6973 GB, free: 1.66 MB / 0.5573 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0006128/2.25, allocations: 4.094 kB / 0.6973 GB, free: 1.66 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:71:3-72:53:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:73:3-74:53:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:78:3-79:55:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:80:3-81:51:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/ElectroMechanics/BoundaryConditions/SourceMechanicalPower.mo:5:3-9:24:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005347/2.25, allocations: 134.9 kB / 0.6975 GB, free: 1.66 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 8.418e-05/2.25, allocations: 41.03 kB / 0.6975 GB, free: 1.66 MB / 0.5573 GB