startTime=0 stopTime=50 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.02 Regular simulation: ./ThermoPower_ThermoPower.Test.WaterComponents.TestBarometricCondenser -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00289511s reading init.xml | | | | | | 0.00029337s reading info.xml | | | | | | 6.8338e-05s [ 0.0%] pre-initialization | | | | | | 0.0241598s [ 3.7%] initialization | | | | | | 6.8488e-05s [ 0.0%] steps | | | | | | 0.00152685s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00120351s [ 0.2%] event-handling | | | | | | 0.0136081s [ 2.1%] overhead | | | | | | 0.605036s [ 93.7%] simulation | | | | | | 0.645671s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 173 steps taken | | | | | | 210 calls of functionODE | | | | | | 73 evaluations of jacobian | | | | | | 4 error test failures | | | | | | 0 convergence test failures | | | | | | 0.195374s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.