Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning") translateModel(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001044/0.001044, allocations: 182 kB / 15.98 MB, free: 5.766 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.05584/0.05584, allocations: 10.75 MB / 27.48 MB, free: 1.871 MB / 18.57 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.396/1.396, allocations: 205.1 MB / 235.7 MB, free: 11.74 MB / 202.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001032/0.001032, allocations: 98.31 kB / 285.5 MB, free: 12.86 MB / 234.8 MB Notification: Performance of FrontEnd - loaded program: time 0.001122/0.001122, allocations: 56.14 kB / 345.3 MB, free: 0.9883 MB / 282.8 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2387/0.2399, allocations: 49 MB / 394.3 MB, free: 35.59 MB / 298.8 MB Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning): time 0.006793/0.2467, allocations: 7.885 MB / 402.2 MB, free: 27.66 MB / 298.8 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may not be used in an algorithm section (use translation flag --allowNonStandardModelica=reinitInAlgorithms to ignore). Notification: Performance of FrontEnd: time 0.0003501/0.2471, allocations: 163.8 kB / 402.3 MB, free: 27.5 MB / 298.8 MB