startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./IDEAS_IDEAS.Airflow.Multizone.Examples.ReverseBuoyancy -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0146596s reading init.xml | | | | | | 0.00155554s reading info.xml | | | | | | 0.000106209s [ 0.3%] pre-initialization | | | | | | 0.000156744s [ 0.4%] initialization | | | | | | 6.022e-06s [ 0.0%] steps | | | | | | 0.00201287s [ 4.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00795721s [ 19.2%] event-handling | | | | | | 0.00406296s [ 9.8%] overhead | | | | | | 0.027042s [ 65.4%] simulation | | | | | | 0.041344s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 317 steps taken | | | | | | 482 calls of functionODE | | | | | | 94 evaluations of jacobian | | | | | | 23 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00258255s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.