startTime=0 stopTime=864000 tolerance=1e-08 numberOfIntervals=2500 stepSize=345.6 Regular simulation: ./Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | The following assertion has been violated at time 43200.000000 | | | | subSta.heaPum.m2_flow >= 0.0 and subSta.heaPum.m2_flow <= 100000.0 assert | info | Variable violating min/max constraint: 0.0 <= subSta.heaPum.m2_flow <= 100000.0, has value: -2.75793e-18 assert | info | The following assertion has been violated at time 57888.000000 | | | | subSta.chi.m1_flow >= 0.0 and subSta.chi.m1_flow <= 100000.0 assert | info | Variable violating min/max constraint: 0.0 <= subSta.chi.m1_flow <= 100000.0, has value: -4.36015e-106 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0303858s reading init.xml | | | | | | 0.00314219s reading info.xml | | | | | | 0.000195567s [ 0.2%] pre-initialization | | | | | | 0.0359419s [ 29.4%] initialization | | | | | | 9.528e-06s [ 0.0%] steps | | | | | | 0.00237302s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000917222s [ 0.8%] event-handling | | | | | | 0.0199901s [ 16.4%] overhead | | | | | | 0.0627087s [ 51.3%] simulation | | | | | | 0.122136s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1921 steps taken | | | | | | 3044 calls of functionODE | | | | | | 444 evaluations of jacobian | | | | | | 231 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00139498s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.