startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermalMultiZone -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.582141s reading init.xml | | | | | | 0.0442681s reading info.xml | | | | | | 0.00321093s [ 0.1%] pre-initialization | | | | | | 0.0105327s [ 0.5%] initialization | | | | | | 0.000301456s [ 0.0%] steps | | | | | | 0.0656778s [ 3.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0177573s [ 0.8%] event-handling | | | | | | 0.117728s [ 5.4%] overhead | | | | | | 1.95561s [ 90.1%] simulation | | | | | | 2.17082s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 466 steps taken | | | | | | 652 calls of functionODE | | | | | | 77 evaluations of jacobian | | | | | | 25 error test failures | | | | | | 0 convergence test failures | | | | | | 0.165039s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.