Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled,tolerance=1e-06,outputFormat="empty",numberOfIntervals=900,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled") translateModel(BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled,tolerance=1e-06,outputFormat="empty",numberOfIntervals=900,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.7114/0.7114, allocations: 128.7 MB / 144.5 MB, free: 1.363 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001243/0.001243, allocations: 189.7 kB / 174.2 MB, free: 5.934 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.39/1.39, allocations: 205.1 MB / 408.9 MB, free: 9.668 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009487/0.0009487, allocations: 112.2 kB / 485.1 MB, free: 13.55 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 0.001138/0.001138, allocations: 54.03 kB / 0.558 GB, free: 97.57 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1502/0.1514, allocations: 75.47 MB / 0.6317 GB, free: 33.04 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/HVAC/Emission/ElectricHeater/JouleHeatingPIControlled.mo:4:3-13:28:writable] Error: Class Modelica.Units.SI.Power not found in scope JouleHeatingPIControlled. Notification: Performance of FrontEnd: time 0.001492/0.1529, allocations: 0.5356 MB / 0.6322 GB, free: 32.5 MB / 442.7 MB