Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=1.2096e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=483.84 Regular simulation: ./TransiEnt_TransiEnt.Consumer.Systems.PVBatteryPoolControl.Controller.Check.CheckPBPDispatcher -abortSlowSimulation -alarm=480 -s gbode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.000812123s reading init.xml | | | | | | 6.7296e-05s reading info.xml | | | | | | 5.7838e-05s [ 1.7%] pre-initialization | | | | | | 0.000100349s [ 2.9%] initialization | | | | | | 4.01e-07s [ 0.0%] steps | | | | | | 8.177e-06s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.6427e-05s [ 0.5%] event-handling | | | | | | 0.000564938s [ 16.3%] overhead | | | | | | 0.00272211s [ 78.4%] simulation | | | | | | 0.00347024s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 2 time events | | | | | solver: euler | | | | | | 8758 steps taken | | | | | | 8758 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.