Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation (gbode: the generic bi-rate ODE solver, with the radauIIA3 method): ./ThermofluidStream_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step3Superheater -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS -r=ThermofluidStream_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step3Superheater_gbode_res.mat -s gbode -gbm=radauIIA3 LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance.p_min >= 611.657 and flowResistance.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0087007s reading init.xml | | | | | | 0.000594806s reading info.xml | | | | | | 0.00809454s [ 30.3%] pre-initialization | | | | | | 0.000608332s [ 2.3%] initialization | | | | | | 0.000171623s [ 0.6%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000439571s [ 1.6%] creating output-file | | | | | | 0.000156092s [ 0.6%] event-handling | | | | | | 0.000509685s [ 1.9%] overhead | | | | | | 0.0167702s [ 62.7%] simulation | | | | | | 0.0267501s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 44 steps taken | | | | | | 210 calls of functionODE | | | | | | 16 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 6.972e-06s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.