Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.02 Regular simulation (gbode: the generic bi-rate ODE solver, with the radauIIA3 method): ./ThermofluidStream_ThermofluidStream.FlowControl.Tests.ValveReferenceValues -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS -r=ThermofluidStream_ThermofluidStream.FlowControl.Tests.ValveReferenceValues_gbode_res.mat -s gbode -gbm=radauIIA3 LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/BasicControlValve.mo:40:6-40:225:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.dp_ref": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/BasicControlValve.mo:41:6-41:234:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.rho_ref": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Remove the rho_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/SpecificValveType.mo:55:6-55:225:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref1.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.dp_ref1": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/SpecificValveType.mo:56:6-56:234:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref1.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.rho_ref1": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Remove the rho_ref modifier." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.rho_ref1": Actuator signal out of valid range [0,1]" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.dp_ref1": Actuator signal out of valid range [0,1]" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.reference1": Actuator signal out of valid range [0,1]" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.rho_ref": Actuator signal out of valid range [0,1]" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.dp_ref": Actuator signal out of valid range [0,1]" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((reference1.u_in <= 1.0 and reference1.u_in >= 0.0)) --> "In "ValveReferenceValues.reference": Actuator signal out of valid range [0,1]" LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0324027s reading init.xml | | | | | | 0.00317113s reading info.xml | | | | | | 0.0681383s [ 77.6%] pre-initialization | | | | | | 0.000320993s [ 0.4%] initialization | | | | | | 1.9086e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00316196s [ 3.6%] creating output-file | | | | | | 9.836e-06s [ 0.0%] event-handling | | | | | | 0.00547126s [ 6.2%] overhead | | | | | | 0.0106697s [ 12.2%] simulation | | | | | | 0.0877912s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 103 steps taken | | | | | | 896 calls of functionODE | | | | | | 68 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 8 convergence test failures | | | | | | 0.00021148s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.