Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating,tolerance=0.0001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating") translateModel(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating,tolerance=0.0001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8219/0.8219, allocations: 150.9 MB / 167.1 MB, free: 14.54 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0005006/0.0005006, allocations: 23.95 kB / 205.9 MB, free: 9.055 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1385/0.139, allocations: 31.33 MB / 237.3 MB, free: 5.742 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating): time 1.556/1.695, allocations: 305.9 MB / 0.5304 GB, free: 1.648 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.4332/2.128, allocations: 192.4 MB / 0.7183 GB, free: 0.7227 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001803/2.13, allocations: 32.06 kB / 0.7183 GB, free: 0.7227 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/TwoPhaseCavity.mo:178:3-180:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/TwoPhaseCavity.mo:181:3-183:56:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/TwoPhaseCavity.mo:194:3-196:48:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:80:3-81:83:writable] Warning: Connector C1vap is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:82:3-84:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:85:3-87:24:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:88:3-90:17:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:95:3-97:17:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/Sink.mo:17:3-19:16:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/RefQ.mo:15:3-17:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/RefQ.mo:18:3-19:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/IdealCheckValve.mo:22:3-23:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/IdealCheckValve.mo:24:3-25:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.002039/2.132, allocations: 0.8251 MB / 0.7191 GB, free: 0.7148 MB / 0.5762 GB Notification: Performance of NFTyping.typeBindings: time 0.003657/2.135, allocations: 1.81 MB / 0.7209 GB, free: 0.7031 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.0276/2.163, allocations: 13.33 MB / 0.7339 GB, free: 384 kB / 0.5762 GB Notification: Performance of NFFlatten.flatten: time 0.01792/2.181, allocations: 25.88 MB / 0.7592 GB, free: 15.07 MB / 0.5919 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01082/2.192, allocations: 8.616 MB / 0.7676 GB, free: 11.26 MB / 0.5919 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01192/2.204, allocations: 8.047 MB / 0.7755 GB, free: 7.711 MB / 0.5919 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01379/2.218, allocations: 8.361 MB / 0.7836 GB, free: 2.207 MB / 0.5919 GB Notification: Performance of NFPackage.collectConstants: time 0.004759/2.222, allocations: 1.762 MB / 0.7854 GB, free: 452 kB / 0.5919 GB Notification: Performance of NFFlatten.collectFunctions: time 0.04226/2.265, allocations: 22.84 MB / 0.8077 GB, free: 10.15 MB / 0.6231 GB Notification: Performance of NFScalarize.scalarize: time 0.007637/2.272, allocations: 5.783 MB / 0.8133 GB, free: 4.496 MB / 0.6231 GB Notification: Performance of NFVerifyModel.verify: time 0.017/2.289, allocations: 8.367 MB / 0.8215 GB, free: 12.23 MB / 0.6387 GB Notification: Performance of NFConvertDAE.convert: time 0.04506/2.334, allocations: 31.85 MB / 0.8526 GB, free: 13.73 MB / 0.67 GB Notification: Performance of FrontEnd - DAE generated: time 6.242e-06/2.335, allocations: 0 / 0.8526 GB, free: 13.73 MB / 0.67 GB Notification: Performance of FrontEnd: time 2.063e-06/2.335, allocations: 4 kB / 0.8526 GB, free: 13.72 MB / 0.67 GB Notification: Performance of Transformations before backend: time 0.0005026/2.335, allocations: 0 / 0.8526 GB, free: 13.72 MB / 0.67 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 3704 * Number of variables: 3704 Notification: Performance of Generate backend data structure: time 0.06088/2.396, allocations: 16.88 MB / 0.8691 GB, free: 12.76 MB / 0.6856 GB Notification: Performance of prepare preOptimizeDAE: time 3.934e-05/2.396, allocations: 8.031 kB / 0.8691 GB, free: 12.75 MB / 0.6856 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.004982/2.401, allocations: 1.25 MB / 0.8703 GB, free: 11.49 MB / 0.6856 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01198/2.413, allocations: 5.053 MB / 0.8752 GB, free: 6.418 MB / 0.6856 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.003032/2.416, allocations: 3.032 MB / 0.8782 GB, free: 2.883 MB / 0.6856 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.003775/2.42, allocations: 0.9603 MB / 0.8791 GB, free: 1.922 MB / 0.6856 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.04219/2.462, allocations: 20.26 MB / 0.8989 GB, free: 13.4 MB / 0.7169 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.000253/2.462, allocations: 11.88 kB / 0.8989 GB, free: 13.39 MB / 0.7169 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.002471/2.465, allocations: 359.9 kB / 0.8993 GB, free: 13.04 MB / 0.7169 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.000432/2.465, allocations: 0.527 MB / 0.8998 GB, free: 12.51 MB / 0.7169 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.04232/2.508, allocations: 19.88 MB / 0.9192 GB, free: 8.605 MB / 0.7325 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.3967/2.904, allocations: 70.55 MB / 0.9881 GB, free: 399.4 MB / 0.795 GB Notification: Performance of preOpt comSubExp (simulation): time 0.06804/2.972, allocations: 22.78 MB / 1.01 GB, free: 398.5 MB / 0.795 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.02304/2.995, allocations: 13.76 MB / 1.024 GB, free: 393.7 MB / 0.795 GB Notification: Performance of preOpt evalFunc (simulation): time 0.3962/3.392, allocations: 226.9 MB / 1.245 GB, free: 165.2 MB / 0.795 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.02662/3.418, allocations: 14.24 MB / 1.259 GB, free: 150.9 MB / 0.795 GB Notification: Performance of pre-optimization done (n=2594): time 1.664e-05/3.418, allocations: 2.531 kB / 1.259 GB, free: 150.9 MB / 0.795 GB Notification: Performance of matching and sorting (n=2595): time 0.4959/3.914, allocations: 134.5 MB / 1.391 GB, free: 14.25 MB / 0.795 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001099/3.914, allocations: 271 kB / 1.391 GB, free: 13.94 MB / 0.795 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.002599/3.917, allocations: 2.316 MB / 1.393 GB, free: 11.6 MB / 0.795 GB Notification: Performance of collectPreVariables (initialization): time 0.003517/3.921, allocations: 225.7 kB / 1.393 GB, free: 11.38 MB / 0.795 GB Notification: Performance of collectInitialEqns (initialization): time 0.001268/3.922, allocations: 2.237 MB / 1.396 GB, free: 9.129 MB / 0.795 GB Notification: Performance of collectInitialBindings (initialization): time 0.00781/3.93, allocations: 8.692 MB / 1.404 GB, free: 0.5078 MB / 0.795 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.1782/4.108, allocations: 2.964 MB / 1.407 GB, free: 396.3 MB / 0.795 GB Notification: Performance of setup shared object (initialization): time 3.93e-05/4.108, allocations: 304.8 kB / 1.407 GB, free: 396 MB / 0.795 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.02323/4.131, allocations: 11.76 MB / 1.419 GB, free: 395.9 MB / 0.795 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.02503/4.156, allocations: 13.74 MB / 1.432 GB, free: 392.5 MB / 0.795 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.04966/4.206, allocations: 28.08 MB / 1.46 GB, free: 379.5 MB / 0.795 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 5.196e-05/4.206, allocations: 7.594 kB / 1.46 GB, free: 379.5 MB / 0.795 GB Notification: Performance of matching and sorting (n=2895) (initialization): time 0.09756/4.304, allocations: 42.42 MB / 1.501 GB, free: 351.6 MB / 0.795 GB Notification: Performance of prepare postOptimizeDAE: time 5.23e-05/4.304, allocations: 19.94 kB / 1.501 GB, free: 351.6 MB / 0.795 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001552/4.304, allocations: 69.45 kB / 1.501 GB, free: 351.5 MB / 0.795 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.363/5.667, allocations: 0.6486 GB / 2.15 GB, free: 270.2 MB / 0.795 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002166/5.669, allocations: 0.5347 MB / 2.15 GB, free: 269.8 MB / 0.795 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1094/5.778, allocations: 50.62 MB / 2.2 GB, free: 234.9 MB / 0.795 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01468/5.793, allocations: 0.7666 MB / 2.2 GB, free: 234.4 MB / 0.795 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.002844/5.796, allocations: 0.5443 MB / 2.201 GB, free: 234 MB / 0.795 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 113 * Number of states: 0 () * Number of discrete variables: 53 ($PRE.checkValve.touvert,$whenCondition2,$PRE.checkValve.tferme,$whenCondition1,checkValve.tferme,checkValve.touvert,checkValve.ouvert,$PRE.checkValve.ouvert,PressureLoss_Steam.C2.b,PressureLoss_Steam.C1.a,singularPressureLossPurge.C2.b,singularPressureLossPurge.C1.a,checkValve.C1.a,checkValve.C2.b,refQ.C2.b,refQ.C1.a,sourceP1.C.b,singularPressureLossWaterOut.C2.b,singularPressureLossWaterOut.C1.a,singularPressureLossWaterIn.C2.b,singularPressureLossWaterIn.C1.a,Puit_condenseur2.C.a,WaterHeating.volumeD1.Cs3.b,WaterHeating.volumeD1.Cs2.b,WaterHeating.volumeD1.Cs1.b,WaterHeating.volumeD1.Ce.a,WaterHeating.volumeD.Cs3.b,WaterHeating.volumeD.Cs2.b,WaterHeating.volumeD.Cs1.b,WaterHeating.volumeD.Ce.a,WaterHeating.volumeC.Ce3.a,WaterHeating.volumeC.Cs.b,WaterHeating.volumeC.Ce2.a,WaterHeating.volumeC.Ce1.a,WaterHeating.pipe_2.C2.b,WaterHeating.pipe_2.C1.a,WaterHeating.pipe_1.C2.b,WaterHeating.pipe_1.C1.a,WaterHeating.pipe_3.C2.b,WaterHeating.pipe_3.C1.a,WaterHeating.WaterHeating.Ce.a,WaterHeating.WaterHeating.Cl.b,WaterHeating.WaterHeating.Cv.a,ControlValve_eau.C2.b,ControlValve_eau.C1.a,Puit_condenseur1.C.a,sourceP.C.b,WaterHeating.C1.b,WaterHeating.volumeD1.Cs2.a,WaterHeating.volumeD1.Cs1.a,WaterHeating.volumeD.Cs3.a,WaterHeating.volumeC.Ce2.b,WaterHeating.WaterHeating.NbTubT) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (391): * Single equations (assignments): 333 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 54 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 1 * Torn equation systems: 3 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 1 system {1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 3 systems {(1,3), (1,3), (178,843)} Notification: Performance of prepare postOptimizeDAE: time 0.008095/5.804, allocations: 3.488 MB / 2.204 GB, free: 231.1 MB / 0.795 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.00256/5.807, allocations: 0.8647 MB / 2.205 GB, free: 230.7 MB / 0.795 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.1606/5.967, allocations: 58.22 MB / 2.262 GB, free: 183.8 MB / 0.795 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1511/6.118, allocations: 51.94 MB / 2.313 GB, free: 132.8 MB / 0.795 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001421/6.119, allocations: 20 kB / 2.313 GB, free: 132.8 MB / 0.795 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0003997/6.119, allocations: 107.6 kB / 2.313 GB, free: 132.7 MB / 0.795 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.396/6.515, allocations: 86.64 MB / 2.397 GB, free: 367.6 MB / 0.795 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0003488/6.515, allocations: 44.7 kB / 2.397 GB, free: 367.6 MB / 0.795 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.04309/6.559, allocations: 7.92 MB / 2.405 GB, free: 361.5 MB / 0.795 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1056/6.664, allocations: 22.48 MB / 2.427 GB, free: 339.2 MB / 0.795 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.004819/6.669, allocations: 0.6869 MB / 2.428 GB, free: 338.5 MB / 0.795 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.2288/6.898, allocations: 155.1 MB / 2.579 GB, free: 173.8 MB / 0.795 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 4.338e-06/6.898, allocations: 7.562 kB / 2.579 GB, free: 173.8 MB / 0.795 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1892/7.087, allocations: 70.41 MB / 2.648 GB, free: 103 MB / 0.795 GB Notification: Performance of postOpt removeConstants (simulation): time 0.01114/7.098, allocations: 3.754 MB / 2.652 GB, free: 99.17 MB / 0.795 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.004467/7.103, allocations: 0.5193 MB / 2.652 GB, free: 98.65 MB / 0.795 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.01448/7.117, allocations: 0.7922 MB / 2.653 GB, free: 97.86 MB / 0.795 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.005479/7.123, allocations: 1.515 MB / 2.654 GB, free: 96.36 MB / 0.795 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.003287/7.126, allocations: 0.6441 MB / 2.655 GB, free: 95.71 MB / 0.795 GB Notification: Performance of sorting global known variables: time 0.001989/7.128, allocations: 1.504 MB / 2.657 GB, free: 94.2 MB / 0.795 GB Notification: Performance of sort global known variables: time 2.7e-07/7.128, allocations: 0 / 2.657 GB, free: 94.2 MB / 0.795 GB Notification: Performance of remove unused functions: time 0.01821/7.146, allocations: 6.183 MB / 2.663 GB, free: 88.18 MB / 0.795 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 11 * Number of states: 173 (WaterHeating.WaterHeating.P,WaterHeating.WaterHeating.hl,WaterHeating.WaterHeating.hv,WaterHeating.WaterHeating.Vv,WaterHeating.WaterHeating.Tp,WaterHeating.pipe_3.P[2],WaterHeating.pipe_3.P[3],WaterHeating.pipe_3.P[4],WaterHeating.pipe_3.P[5],WaterHeating.pipe_3.P[6],WaterHeating.pipe_3.P[7],WaterHeating.pipe_3.P[8],WaterHeating.pipe_3.P[9],WaterHeating.pipe_3.P[10],WaterHeating.pipe_3.P[11],WaterHeating.pipe_3.P[12],WaterHeating.pipe_3.P[13],WaterHeating.pipe_3.P[14],WaterHeating.pipe_3.P[15],WaterHeating.pipe_3.P[16],WaterHeating.pipe_3.P[17],WaterHeating.pipe_3.P[18],WaterHeating.pipe_3.P[19],WaterHeating.pipe_3.P[20],WaterHeating.pipe_3.P[21],WaterHeating.pipe_3.Q[1],WaterHeating.pipe_3.Q[2],WaterHeating.pipe_3.Q[3],WaterHeating.pipe_3.Q[4],WaterHeating.pipe_3.Q[5],WaterHeating.pipe_3.Q[6],WaterHeating.pipe_3.Q[7],WaterHeating.pipe_3.Q[8],WaterHeating.pipe_3.Q[9],WaterHeating.pipe_3.Q[10],WaterHeating.pipe_3.Q[11],WaterHeating.pipe_3.Q[12],WaterHeating.pipe_3.Q[13],WaterHeating.pipe_3.Q[14],WaterHeating.pipe_3.Q[15],WaterHeating.pipe_3.Q[16],WaterHeating.pipe_3.Q[17],WaterHeating.pipe_3.Q[18],WaterHeating.pipe_3.Q[19],WaterHeating.pipe_3.Q[20],WaterHeating.pipe_3.Q[21],WaterHeating.pipe_3.h[2],WaterHeating.pipe_3.h[3],WaterHeating.pipe_3.h[4],WaterHeating.pipe_3.h[5],WaterHeating.pipe_3.h[6],WaterHeating.pipe_3.h[7],WaterHeating.pipe_3.h[8],WaterHeating.pipe_3.h[9],WaterHeating.pipe_3.h[10],WaterHeating.pipe_3.h[11],WaterHeating.pipe_3.h[12],WaterHeating.pipe_3.h[13],WaterHeating.pipe_3.h[14],WaterHeating.pipe_3.h[15],WaterHeating.pipe_3.h[16],WaterHeating.pipe_3.h[17],WaterHeating.pipe_3.h[18],WaterHeating.pipe_3.h[19],WaterHeating.pipe_3.h[20],WaterHeating.pipe_3.h[21],WaterHeating.Wall_3.Tp[1],WaterHeating.Wall_3.Tp[2],WaterHeating.Wall_3.Tp[3],WaterHeating.Wall_3.Tp[4],WaterHeating.Wall_3.Tp[5],WaterHeating.Wall_3.Tp[6],WaterHeating.Wall_3.Tp[7],WaterHeating.Wall_3.Tp[8],WaterHeating.Wall_3.Tp[9],WaterHeating.Wall_3.Tp[10],WaterHeating.Wall_3.Tp[11],WaterHeating.Wall_3.Tp[12],WaterHeating.Wall_3.Tp[13],WaterHeating.Wall_3.Tp[14],WaterHeating.Wall_3.Tp[15],WaterHeating.Wall_3.Tp[16],WaterHeating.Wall_3.Tp[17],WaterHeating.Wall_3.Tp[18],WaterHeating.Wall_3.Tp[19],WaterHeating.Wall_3.Tp[20],WaterHeating.pipe_1.P[2],WaterHeating.pipe_1.P[3],WaterHeating.pipe_1.P[4],WaterHeating.pipe_1.P[5],WaterHeating.pipe_1.P[6],WaterHeating.pipe_1.P[7],WaterHeating.pipe_1.P[8],WaterHeating.pipe_1.P[9],WaterHeating.pipe_1.P[10],WaterHeating.pipe_1.P[11],WaterHeating.pipe_1.Q[1],WaterHeating.pipe_1.Q[2],WaterHeating.pipe_1.Q[3],WaterHeating.pipe_1.Q[4],WaterHeating.pipe_1.Q[5],WaterHeating.pipe_1.Q[6],WaterHeating.pipe_1.Q[7],WaterHeating.pipe_1.Q[8],WaterHeating.pipe_1.Q[9],WaterHeating.pipe_1.Q[10],WaterHeating.pipe_1.Q[11],WaterHeating.pipe_1.h[2],WaterHeating.pipe_1.h[3],WaterHeating.pipe_1.h[4],WaterHeating.pipe_1.h[5],WaterHeating.pipe_1.h[6],WaterHeating.pipe_1.h[7],WaterHeating.pipe_1.h[8],WaterHeating.pipe_1.h[9],WaterHeating.pipe_1.h[10],WaterHeating.pipe_1.h[11],WaterHeating.Wall_1.Tp[1],WaterHeating.Wall_1.Tp[2],WaterHeating.Wall_1.Tp[3],WaterHeating.Wall_1.Tp[4],WaterHeating.Wall_1.Tp[5],WaterHeating.Wall_1.Tp[6],WaterHeating.Wall_1.Tp[7],WaterHeating.Wall_1.Tp[8],WaterHeating.Wall_1.Tp[9],WaterHeating.Wall_1.Tp[10],WaterHeating.pipe_2.P[2],WaterHeating.pipe_2.P[3],WaterHeating.pipe_2.P[4],WaterHeating.pipe_2.P[5],WaterHeating.pipe_2.P[6],WaterHeating.pipe_2.P[7],WaterHeating.pipe_2.P[8],WaterHeating.pipe_2.P[9],WaterHeating.pipe_2.P[10],WaterHeating.pipe_2.P[11],WaterHeating.pipe_2.Q[1],WaterHeating.pipe_2.Q[2],WaterHeating.pipe_2.Q[3],WaterHeating.pipe_2.Q[4],WaterHeating.pipe_2.Q[5],WaterHeating.pipe_2.Q[6],WaterHeating.pipe_2.Q[7],WaterHeating.pipe_2.Q[8],WaterHeating.pipe_2.Q[9],WaterHeating.pipe_2.Q[10],WaterHeating.pipe_2.Q[11],WaterHeating.pipe_2.h[2],WaterHeating.pipe_2.h[3],WaterHeating.pipe_2.h[4],WaterHeating.pipe_2.h[5],WaterHeating.pipe_2.h[6],WaterHeating.pipe_2.h[7],WaterHeating.pipe_2.h[8],WaterHeating.pipe_2.h[9],WaterHeating.pipe_2.h[10],WaterHeating.pipe_2.h[11],WaterHeating.Wall_2.Tp[1],WaterHeating.Wall_2.Tp[2],WaterHeating.Wall_2.Tp[3],WaterHeating.Wall_2.Tp[4],WaterHeating.Wall_2.Tp[5],WaterHeating.Wall_2.Tp[6],WaterHeating.Wall_2.Tp[7],WaterHeating.Wall_2.Tp[8],WaterHeating.Wall_2.Tp[9],WaterHeating.Wall_2.Tp[10],WaterHeating.volumeC.P,WaterHeating.volumeC.h,WaterHeating.volumeD.h,WaterHeating.volumeD1.P,WaterHeating.volumeD1.h) * Number of discrete variables: 5 ($whenCondition2,$whenCondition1,checkValve.ouvert,checkValve.touvert,checkValve.tferme) * Number of discrete states: 2 (checkValve.touvert,checkValve.tferme) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (1925): * Single equations (assignments): 1656 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 140 * When equations: 1 * If-equations: 0 * Equation systems (not torn): 42 * Torn equation systems: 86 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 42 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 42 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 44 systems {(1,3), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (3,7), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (2,6), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (4,10), (1,3), (1,4)} Notification: Performance of Backend phase and start with SimCode phase: time 0.01008/7.156, allocations: 3.074 MB / 2.666 GB, free: 85.75 MB / 0.795 GB Notification: Performance of simCode: created initialization part: time 0.09346/7.25, allocations: 53.74 MB / 2.718 GB, free: 29.49 MB / 0.795 GB Notification: Performance of simCode: created event and clocks part: time 7.474e-06/7.25, allocations: 2.625 kB / 2.718 GB, free: 29.49 MB / 0.795 GB Notification: Performance of simCode: created simulation system equations: time 0.2328/7.483, allocations: 33.07 MB / 2.75 GB, free: 346.7 MB / 0.795 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.02873/7.511, allocations: 6.474 MB / 2.757 GB, free: 346.4 MB / 0.795 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.09957/7.611, allocations: 51.97 MB / 2.807 GB, free: 331.8 MB / 0.795 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.009807/7.621, allocations: 9.517 MB / 2.817 GB, free: 330.4 MB / 0.795 GB Notification: Performance of simCode: alias equations: time 0.01031/7.631, allocations: 3.223 MB / 2.82 GB, free: 329.8 MB / 0.795 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.003278/7.635, allocations: 0.8899 MB / 2.821 GB, free: 329.8 MB / 0.795 GB Notification: Performance of SimCode: time 6.51e-07/7.635, allocations: 0 / 2.821 GB, free: 329.8 MB / 0.795 GB Notification: Performance of Templates: time 0.9699/8.604, allocations: 0.5295 GB / 3.35 GB, free: 355.8 MB / 0.795 GB make -j1 -f ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.makefile (rm -f ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.pipe >> ../files/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.sim & ./ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating -abortSlowSimulation -alarm=480 -s gbode -lv LOG_STATS > ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating.pipe 2>&1)