Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=36000 stepSize=0.1 Regular simulation: ./Modelica_4.1.0-beta.om_Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge -abortSlowSimulation -alarm=480 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00802099s reading init.xml | | | | | | 0.000593263s reading info.xml | | | | | | 0.000682419s [ 0.5%] pre-initialization | | | | | | 0.00012819s [ 0.1%] initialization | | | | | | 2.7903e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0146064s [ 10.4%] creating output-file | | | | | | 0.000311586s [ 0.2%] event-handling | | | | | | 0.0194978s [ 13.9%] overhead | | | | | | 0.104891s [ 74.8%] simulation | | | | | | 0.140146s [100.0%] total | | | | | events | | | | | | 28 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 1816 steps taken | | | | | | 34872 calls of functionODE | | | | | | 149 evaluations of jacobian | | | | | | 6 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.