Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./IDEAS_dev_IDEAS.Airflow.Multizone.Examples.CO2TransportStep -abortSlowSimulation -alarm=480 -s gbode -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenTop.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenTop can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenTop." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenWes.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenWes can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenWes." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenEas.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenEas can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IDEAS.Fluid.MixingVolumes`. | | | | See IDEAS.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenEas." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 4180.08. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 51697.6. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 59719.1. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 60407.3. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 70313.5. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 73088.7. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 84432.9. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0112874s reading init.xml | | | | | | 0.000787517s reading info.xml | | | | | | 0.000221666s [ 0.2%] pre-initialization | | | | | | 0.000173826s [ 0.2%] initialization | | | | | | 9.708e-06s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 4.265e-06s [ 0.0%] event-handling | | | | | | 0.00376592s [ 4.0%] overhead | | | | | | 0.089773s [ 95.6%] simulation | | | | | | 0.0939484s [100.0%] total | | | | | events | | | | | | 9 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 248 steps taken | | | | | | 128619 calls of functionODE | | | | | | 3319 evaluations of jacobian | | | | | | 88 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.