Environment - simulationEnvironment: startTime=0 stopTime=186360 tolerance=1e-06 numberOfIntervals=2500 stepSize=74.544 Regular simulation: ./IBPSA_latest_IBPSA.Fluid.Geothermal.Borefields.Validation.Sandbox -abortSlowSimulation -alarm=480 -s gbode -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_STDOUT | info | ... loading "data" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Resources/Data/Fluid/Geothermal/Borefields/HeatTransfer/Validation/Beier_Smith_Spitler_2011_SandBox.txt" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/1d2f5fcf3b3ff954b7c65c809e2f939106c2fa87TStep.mat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pum.per.etaHydMet == IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Sandbox.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Sandbox.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Media/Water.mo:65:5-66:118:writable] | | | | The following assertion has been violated at time 102982.536000 | | | | ((noEvent(borHol.borHol.intHex[1].vol1.dynBal.medium.T <= 403.15))) --> "In Sandbox.borHol.borHol.intHex[1].vol1.dynBal.medium: Temperature T = 403.167 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "IBPSA.Media.Water"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now!