Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.SMIB.SMIBStepPm.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00132/0.00132, allocations: 115.5 kB / 18.88 MB, free: 3.062 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001536/0.001536, allocations: 192.4 kB / 22.17 MB, free: 5.656 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.482/1.482, allocations: 207.6 MB / 232.9 MB, free: 10.96 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo): time 0.6254/0.6254, allocations: 103 MB / 388.1 MB, free: 21.08 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(Dynawo.Examples.SMIB.SMIBStepPm,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_dev_Dynawo.Examples.SMIB.SMIBStepPm") translateModel(Dynawo.Examples.SMIB.SMIBStepPm,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_dev_Dynawo.Examples.SMIB.SMIBStepPm") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002393/0.002393, allocations: 71.88 kB / 0.5489 GB, free: 1.965 MB / 462.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3132/0.3156, allocations: 75.65 MB / 0.6228 GB, free: 11.82 MB / 462.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SMIB.SMIBStepPm): time 0.003858/0.3194, allocations: 4.087 MB / 0.6268 GB, free: 7.711 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.003837/0.3233, allocations: 3.97 MB / 0.6307 GB, free: 3.711 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.00027/0.3235, allocations: 15.94 kB / 0.6307 GB, free: 3.695 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:24:3-24:104:writable] Warning: Connector omegaRefPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:25:3-25:94:writable] Warning: Connector PmPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:26:3-26:125:writable] Warning: Connector efdPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:29:3-29:96:writable] Warning: Connector omegaPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:42:3-42:108:writable] Warning: Connector UStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:43:3-43:115:writable] Warning: Connector IStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:44:3-44:116:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:45:3-45:126:writable] Warning: Connector QStatorPuQNom is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:46:3-46:123:writable] Warning: Connector IRotorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:47:3-47:95:writable] Warning: Connector thetaInternal is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/Step.mo:17:3-17:54:writable] Warning: Connector step is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SetPoint.mo:17:3-17:75:writable] Warning: Connector setPoint is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005749/0.3241, allocations: 182.1 kB / 0.6308 GB, free: 3.52 MB / 462.1 MB Notification: Performance of NFTyping.typeBindings: time 0.0004951/0.3246, allocations: 234.3 kB / 0.6311 GB, free: 3.289 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/SMIBStepPm.mo:92:3-92:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/SMIBStepPm.mo:94:3-94:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/SMIBStepPm.mo:96:3-96:45:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/SMIBStepPm.mo:98:3-98:54:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/SMIBStepPm.mo:99:3-99:54:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:133:3-133:117:writable] Warning: In relation generatorSynchronous.SNom <> generatorSynchronous.PNomAlt, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.001947/0.3266, allocations: 1.039 MB / 0.6321 GB, free: 2.25 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:51:3-51:114:writable] Error: Parameter generatorSynchronous.MdPPuEfd has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0004263/0.327, allocations: 458.3 kB / 0.6325 GB, free: 1.801 MB / 462.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.3932460928335786] Failed to read output from testmodel.py, exit status != 0: 0.33421684708446264 0.347910265 -1.0 Calling exit ...