Environment - simulationEnvironment: startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.ZoneCapacitanceMultiplier -abortSlowSimulation -alarm=800 -s gbode -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2024.12.21 15:12 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2024.12.21 15:13 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((mulCap.duc.m_flow >= 0.0 and mulCap.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= mulCap.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((defCap.duc.m_flow >= 0.0 and defCap.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= defCap.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0158633s reading init.xml | | | | | | 0.00129421s reading info.xml | | | | | | 0.000225934s [ 0.0%] pre-initialization | | | | | | 14.7503s [ 90.7%] initialization | | | | | | 0.00012831s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.577691s [ 3.6%] event-handling | | | | | | 0.00937529s [ 0.1%] overhead | | | | | | 0.918435s [ 5.6%] simulation | | | | | | 16.2561s [100.0%] total | | | | | events | | | | | | 719 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 36151 steps taken | | | | | | 382600 calls of functionODE | | | | | | 2142 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 9.08sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 1.83sec EnergyPlus Completed Successfully.