Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalTwoZoneBuildings -abortSlowSimulation -alarm=800 -s gbode -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2024.12.21 15:11 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output TwoIdenticalTwoZoneBuildings.bui.inf1.y has in Modelica the unit 1. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0282572s reading init.xml | | | | | | 0.00236799s reading info.xml | | | | | | 0.000231054s [ 0.0%] pre-initialization | | | | | | 7.18462s [ 91.7%] initialization | | | | | | 0.00010149s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0745457s [ 1.0%] event-handling | | | | | | 0.00732712s [ 0.1%] overhead | | | | | | 0.571131s [ 7.3%] simulation | | | | | | 7.83796s [100.0%] total | | | | | events | | | | | | 287 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 12513 steps taken | | | | | | 131894 calls of functionODE | | | | | | 15 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.82sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. Limited backtrace at point of segmentation fault /lib/x86_64-linux-gnu/libc.so.6(+0x42520)[0x7fed0d203520] [0x55ff68e6f430]