Environment - simulationEnvironment: startTime=1.0368e+07 stopTime=1.05408e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass -abortSlowSimulation -alarm=480 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in CoolingTowersWithBypass.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in CoolingTowersWithBypass.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 10369590.037994 | | | | ((tow.cooTowSys.cooTow[1].per.FRWat >= 0.0 and tow.cooTowSys.cooTow[1].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.cooTowSys.cooTow[1].per.FRWat <= 1.0, has value: -5.56142e-37" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 10386524.160000 | | | | ((tow.cooTowSys.cooTow[2].per.FRWat >= 0.0 and tow.cooTowSys.cooTow[2].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.cooTowSys.cooTow[2].per.FRWat <= 1.0, has value: -7.50512e-307" LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0221988s reading init.xml | | | | | | 0.00203526s reading info.xml | | | | | | 0.000785684s [ 0.0%] pre-initialization | | | | | | 0.0291517s [ 0.6%] initialization | | | | | | 0.00020231s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00565924s [ 0.1%] creating output-file | | | | | | 0.0116191s [ 0.2%] event-handling | | | | | | 0.0260857s [ 0.5%] overhead | | | | | | 4.68102s [ 98.5%] simulation | | | | | | 4.75452s [100.0%] total | | | | | events | | | | | | 246 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 14783 steps taken | | | | | | 467149 calls of functionODE | | | | | | 5735 evaluations of jacobian | | | | | | 2095 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.