Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-08 numberOfIntervals=2500 stepSize=345.6 Regular simulation: ./Buildings_9_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT -abortSlowSimulation -alarm=480 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 43200.000000 | | | | ((subSta.heaPum.m2_flow >= 0.0 and subSta.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= subSta.heaPum.m2_flow <= 1e5, has value: -2.35199e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 58406.400000 | | | | ((subSta.chi.m1_flow >= 0.0 and subSta.chi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= subSta.chi.m1_flow <= 1e5, has value: -1.64893e-229" LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 124887. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 182462. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 210776. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 271450. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 273195. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 462647. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0301621s reading init.xml | | | | | | 0.00262131s reading info.xml | | | | | | 0.00108848s [ 0.5%] pre-initialization | | | | | | 0.0321436s [ 13.4%] initialization | | | | | | 4.264e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00379692s [ 1.6%] creating output-file | | | | | | -2.11758e-21s [ -0.0%] event-handling | | | | | | 0.0235924s [ 9.9%] overhead | | | | | | 0.178618s [ 74.6%] simulation | | | | | | 0.239289s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 1391 steps taken | | | | | | 31082 calls of functionODE | | | | | | 171 evaluations of jacobian | | | | | | 265 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.