Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-07 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_9_Buildings.Examples.Tutorial.Boiler.System7 -abortSlowSimulation -alarm=480 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumRad.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumBoi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 16802.9. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 28800. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 81344.5. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0738498s reading init.xml | | | | | | 0.0052384s reading info.xml | | | | | | 0.00103861s [ 0.0%] pre-initialization | | | | | | 0.0322695s [ 0.3%] initialization | | | | | | 0.00341648s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0150685s [ 0.1%] creating output-file | | | | | | 0.028515s [ 0.2%] event-handling | | | | | | 0.0538594s [ 0.4%] overhead | | | | | | 12.1505s [ 98.9%] simulation | | | | | | 12.2846s [100.0%] total | | | | | events | | | | | | 758 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 38997 steps taken | | | | | | 998895 calls of functionODE | | | | | | 11205 evaluations of jacobian | | | | | | 429 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.