Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Components.Validation.Pumps.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001379/0.001379, allocations: 104.3 kB / 19.7 MB, free: 2.156 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001485/0.001485, allocations: 212.4 kB / 22.99 MB, free: 4.984 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.489/1.489, allocations: 230.6 MB / 256.8 MB, free: 7.781 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.171/3.171, allocations: 0.49 GB / 0.7958 GB, free: 35.31 MB / 0.6231 GB " [Timeout remaining time 176] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_12_Buildings.Templates.Components.Validation.Pumps") translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_12_Buildings.Templates.Components.Validation.Pumps") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002105/0.002105, allocations: 74.2 kB / 1.155 GB, free: 25.2 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3311/0.3332, allocations: 176.1 MB / 1.327 GB, free: 0.957 MB / 1.014 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Components.Validation.Pumps): time 1.12/1.453, allocations: 406.5 MB / 1.724 GB, free: 51.37 MB / 1.295 GB Notification: Performance of NFInst.instExpressions: time 0.1116/1.565, allocations: 90.99 MB / 1.813 GB, free: 4.086 MB / 1.295 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01826/1.583, allocations: 0.728 MB / 1.814 GB, free: 3.703 MB / 1.295 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/Characteristics/flowParameters.mo:5:3-6:57:writable] Error: Dimension 1 of 'V_flow' could not be deduced from the component's binding equation 'datPumMul.per.pressure.V_flow'. Notification: Performance of FrontEnd: time 0.00315/1.586, allocations: 1.284 MB / 1.815 GB, free: 2.977 MB / 1.295 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 8.11440118700557] Failed to read output from testmodel.py, exit status != 0: 1.5926332279923372 1.606151568 -1.0 Calling exit ...