Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3 -abortSlowSimulation -alarm=400 -s gbode -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones3.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable North_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.&##10;" LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.&##10;" LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.&##10;" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00530285s reading init.xml | | | | | | 0.000557675s reading info.xml | | | | | | 0.000176712s [ 0.2%] pre-initialization | | | | | | 0.0644512s [ 78.1%] initialization | | | | | | 2.2392e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00294691s [ 3.6%] event-handling | | | | | | 0.0023527s [ 2.9%] overhead | | | | | | 0.01255s [ 15.2%] simulation | | | | | | 0.0824999s [100.0%] total | | | | | events | | | | | | 59 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 2148 steps taken | | | | | | 16803 calls of functionODE | | | | | | 2 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.