Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.008 Regular simulation: ./Buildings_11_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Validation.FiniteLineSource -abortSlowSimulation -alarm=400 -s gbode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00086354s reading init.xml | | | | | | 0.000101871s reading info.xml | | | | | | 0.000394319s [ 0.0%] pre-initialization | | | | | | 7.1054e-05s [ 0.0%] initialization | | | | | | 0.013107s [ 0.1%] steps | | | | | | 3.7604e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00138648s [ 0.0%] creating output-file | | | | | | 0.00031091s [ 0.0%] event-handling | | | | | | 0.00283895s [ 0.0%] overhead | | | | | | 21.7518s [ 99.9%] simulation | | | | | | 21.77s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2500 steps taken | | | | | | 2500 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.