Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2513 stepSize=240.669 Regular simulation: ./Buildings_11_Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1 -abortSlowSimulation -alarm=400 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.12.19 21:42 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 268069. Number of Iterations 20 LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 268069. Number of Iterations 20 LOG_STDOUT | info | GBODE: Solution of NLS failed, Try with updated Jacobian at time 268069. Number of Iterations 20 LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 433925.348189 | | | | ((bui.terUni.hexHea.m1_flow >= 0.0 and bui.terUni.hexHea.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.terUni.hexHea.m1_flow <= 1e5, has value: -2.67612e-06" LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0510877s reading init.xml | | | | | | 0.00622037s reading info.xml | | | | | | 0.00202393s [ 0.0%] pre-initialization | | | | | | 8.57702s [ 46.7%] initialization | | | | | | 0.00246516s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0167143s [ 0.1%] creating output-file | | | | | | 0.814087s [ 4.4%] event-handling | | | | | | 0.0441657s [ 0.2%] overhead | | | | | | 8.92482s [ 48.6%] simulation | | | | | | 18.3813s [100.0%] total | | | | | events | | | | | | 1007 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 60699 steps taken | | | | | | 1193023 calls of functionODE | | | | | | 7420 evaluations of jacobian | | | | | | 1582 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 10.33sec EnergyPlus Completed Successfully.